  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RSG2488 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 9/2013...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RSG2488 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Management Ports and Indicator LEDs ..................2 Chapter 2 Installing the Device ....................
  • Page 4 RUGGEDCOM RSG2488 Table of Contents Installation Guide 3.2 Fiber Optic Ethernet Ports ......................21 3.3 SFP Optic Ethernet Ports ......................22 3.3.1 Installing an SFP Optical Port ..................23 3.3.2 Removing an SFP Optical Port ..................23 3.4 Installing/Removing Modules ....................... 24 3.4.1 Installing Modules ......................
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG2488. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, please contact Customer Support at: Toll Free (North America): 1 866 922 7975...
  • Page 7: Introduction

    Introduction Introduction The RUGGEDCOM RSG2488 is a utility grade, fully managed, industrial Ethernet switch designed to operate reliably in harsh environments. With a rugged metal enclosure and an optional conformal coating, the RSG2488 provides a high level of immunity to electromagnetic interference and heavy electrical surges, and can withstand temperatures between -40 and 85 °C (-40 and 185 °F).
  • Page 8: Management Ports And Indicator Leds

    Chapter 1 RUGGEDCOM RSG2488 Introduction Installation Guide • Supports Siemens FastConnect RJ45 Cabling System • -40 to 85 °C (-40 to 185 °F) operating temperature (fanless) • Conformal coated printed circuit boards (optional) Section 1.2 Management Ports and Indicator LEDs The RSG2488 features various ports and indicator LEDs on the front panel for configuring and troubleshooting the device.
  • Page 9: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 10: Mounting The Device To A Rack

    Chapter 2 RUGGEDCOM RSG2488 Installing the Device Installation Guide The following sections describe the various methods of mounting the device: • Section 2.1.1, “Mounting the Device to a Rack” • Section 2.1.2, “Mounting the Device on a DIN Rail” •...
  • Page 11: Mounting The Device To A Panel

    RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Figure 3: DIN Rail Mounting 1. DIN Rail 2.
  • Page 12: Connecting Power

    Chapter 2 RUGGEDCOM RSG2488 Installing the Device Installation Guide Figure 4: Panel Mounting 1. Screw 2. Panel/DIN Rail Adaptor Install the supplied screws to secure the adapters to the panel. Section 2.2 Connecting Power The RSG2488 supports dual redundant AC and/or DC power supplies that can be installed in any combination.
  • Page 13: Installing/Removing Power Supplies

    RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device PS1, the high AC/DC wiring must be connected to the high terminal block PS1 terminals. If a low DC power supply is installed in slot PS1, the low DC wiring must be made to the low terminal block PS1 terminals.
  • Page 14: Installing The Power Supplies

    Chapter 2 RUGGEDCOM RSG2488 Installing the Device Installation Guide Section 2.2.1.1 Installing the Power Supplies To install a power supply, do the following: NOTE The power supplies are hot swappable. It is not necessary to disconnect power to the device before installing or removing a power supply.
  • Page 15: Connecting High Ac/Dc Power

    RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Figure 7: Removing a Power Supply 1. Screws 2. Power Supply 3. Slot Install the blank power module assembly into the empy slot to prevent the ingress of dust and dirt.
  • Page 16: Connecting Low Dc Power

    Chapter 2 RUGGEDCOM RSG2488 Installing the Device Installation Guide Figure 8: AC Terminal Block Wiring 1. Pluggable Terminal Block for HI Power Supplies 2. Screw-Type Terminal Block for HIP Power Supplies 3. Positive/Live (+/L) Terminal for PS1 4. Neutral/Negative (-/N) Terminal for PS1 5.
  • Page 17: Wiring Examples

    RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Figure 9: DC Terminal Block Wiring 1. Pluggable Terminal Block for 24P and 48P Power Supply 2. Screw-Type Terminal Block for 24 and 48 Power Supply 3. Positive Terminal for PS1 4.
  • Page 18 Chapter 2 RUGGEDCOM RSG2488 Installing the Device Installation Guide Figure 11: Single Low DC Power Supply Figure 12: Dual High AC/DC Power Supply Wiring Examples...
  • Page 19: Connecting The Failsafe Alarm Relay

    RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Figure 13: Dual Low DC Power Supply Figure 14: Dual High AC/DC Power Supply and Low DC Power Supply Section 2.3 Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 20: Grounding The Device

    Chapter 2 RUGGEDCOM RSG2488 Installing the Device Installation Guide NOTE Control of the failsafe relay output is configurable through ROS. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for the RSG2488.
  • Page 21: Communication Ports

    RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Serial Console and Management Ports Connect a PC or terminal directly to the serial console or management ports to access the boot-time control and ROS interfaces. The serial console port provides access to ROS's console interface, while the management port provides access to ROS's console and Web interfaces.
  • Page 22: Cabling Recommendations

    Section 2.6.1 Protection On Twisted-Pair Data Ports Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 23 RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device • Shielded/screened cabling can be used when required. Care should be taken to avoid the creation of ground loops with shielded cabling. Gigabit Ethernet 1000Base-TX Cabling Recommendations...
  • Page 24 RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Gigabit Ethernet 1000Base-TX Cabling Recommendations...
  • Page 25: Communication Ports

    RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports Communication Ports The RSG2488 can be equipped with various types of communication ports to enhance its abilities and performance. Each set of communication ports is part of a field replaceable module that makes switching ports fast and easy.
  • Page 26: Copper Ethernet Ports

    The RSG2488 supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with RJ45 or Siemens's FastConnect RJ45 male connectors. The RJ45 and FastConnect RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 27: Fiber Optic Ethernet Ports

    RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports Figure 22: 4 × 10/100/1000Base-TX with FastConnect Figure 23: 2 × 10/100/1000Base-TX with FastConnect RJ45 Ports (02) RJ45 Ports (62) Each port features a Speed and Link LED that indicates the state of the port.
  • Page 28: Sfp Optic Ethernet Ports

    Chapter 3 RUGGEDCOM RSG2488 Communication Ports Installation Guide Figure 25: LC Port (05, 07, 10, 17, 19) Figure 26: SC Port (06) 1. Tx Connector 2. Rx Connector 1. Tx Connector 2. Rx Connector Figure 27: ST Port (13, 15) 1.
  • Page 29: Installing An Sfp Optical Port

    To install an SFP optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 30: Installing/Removing Modules

    Chapter 3 RUGGEDCOM RSG2488 Communication Ports Installation Guide CAUTION! Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before performing installing or removing components from the device. An electrostatic discharge (ESD) can cause serious damage to the component once it is outside the chassis.
  • Page 31: Removing Modules

    RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports Figure 31: Installing a Module 1. Module 2. Chassis 3. Screw Tighten the screws to secure the module. If necessary, install the device in the rack. Connect power to the device. Section 3.4.2...
  • Page 32 Chapter 3 RUGGEDCOM RSG2488 Communication Ports Installation Guide Figure 32: Removing a Module 1. Module 2. Chassis 3. Screw Install a new module or a blank module (to prevent the ingress of dust and dirt). For more information, refer Section 3.4.1, “Installing Modules”.
  • Page 33: Technical Specifications

    RUGGEDCOM RSG2488 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Copper Ethernet Port Specifications”...
  • Page 34: Copper Ethernet Port Specifications

    Chapter 4 RUGGEDCOM RSG2488 Technical Specifications Installation Guide Section 4.3 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RSG2488. Wiring Maximum Order Code Speed Connector Duplex Cable Type Isolation...
  • Page 35: Gigabit Ethernet (1 Gbps) Optical Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 36: Supported Networking Standards

    Chapter 4 RUGGEDCOM RSG2488 Technical Specifications Installation Guide Cable Tx λ Distance Power Order Connector Tx min Speed Mode Type (typ.) Sensitivity Saturation (Typ.) Budget Code Type (dBm) (μm) (nm) (dBm) (dBm) (dBm) (km) (dB) 1000Base- 9/125 1310 -9.5 1000Base-...
  • Page 37: Mechanical Specifications

    RUGGEDCOM RSG2488 Chapter 4 Installation Guide Technical Specifications Section 4.7 Mechanical Specifications Parameter Value Dimensions Refer to Chapter 5, Dimension Drawings Weight 8.6 kg (19 lbs) Enclosure Aluminum Mechanical Specifications...
  • Page 38 RUGGEDCOM RSG2488 Chapter 4 Installation Guide Technical Specifications Mechanical Specifications...
  • Page 39: Dimension Drawings

    RUGGEDCOM RSG2488 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 442.4 Figure 33: Overall Dimensions...
  • Page 40 Chapter 5 RUGGEDCOM RSG2488 Dimension Drawings Installation Guide 483.5 465.2 21.1 Figure 34: Rack Mount Dimensions...
  • Page 41 RUGGEDCOM RSG2488 Chapter 5 Installation Guide Dimension Drawings 480.5 490.6 Figure 35: Panel and Din Rail Mount Dimensions 1. DIN Rail Centerline...
  • Page 42 RUGGEDCOM RSG2488 Chapter 5 Installation Guide Dimension Drawings...
  • Page 43: Certification

    RUGGEDCOM RSG2488 Chapter 6 Installation Guide Certification Certification The RSG2488 device has been thoroughly tested to guarantee its conformance with recognized standards and has recieved approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
  • Page 44: Emi And Environmental Type Tests

    Chapter 6 RUGGEDCOM RSG2488 Certification Installation Guide Section 6.4 EMI and Environmental Type Tests The RSG2488 has passed the following EMI and environmental tests. IEC 61850-3 EMI Type Tests NOTE • In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise, all Class 1 requirements are met for copper ports.
  • Page 45: Environmental Type Tests

    Test Description Test Levels Severity Levels D.C. Power Ports IEC 61000-4-17 Ripple on D.C. D.C. Power Ports Power Supply IEC 60255-5 Dialiectric Strength Signal Ports 2 kVAC (Fail- Safe Relay Output) D.C. Power Ports 1.5 kVDC A.C. Power Ports 2 kVAC H.V.