Page 2
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG2200. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
RUGGEDCOM RSG2200 Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
Introduction Introduction The RUGGEDCOM RSG2200 is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility substation, railway and industrial environments. The RUGGEDCOM RSG2200’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reliability and advanced cyber security and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control applications.
Section 1.2 Description The RUGGEDCOM RSG2200 features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
Section 3.1, “Connecting to the Device”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2200: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. CAT-5 Ethernet cables For connecting the device to the network.
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
RUGGEDCOM RSG2200 Chapter 1 Installation Guide Introduction 1000Base- Cabling Category Required Action TX Compliant No action required. > 6 Connector and wiring standards to be determined. Follow these recommendations for copper data cabling in high electrical noise environments: • Data cable lengths should be as short as possible, preferably 3 m (10 ft) in length. Copper data cables should not be used for inter-building communications.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Mounting the Device The RUGGEDCOM RSG2200 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail, or directly on a panel.
Section 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2200 can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2200 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
Section 2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG2200 can be equipped with panelDIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
The RUGGEDCOM RSG2200 supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM RSG2200 can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies. The screw-type terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
RUGGEDCOM RSG2200 Chapter 2 Installation Guide Installing Device • Section 2.5.2, “Wiring Examples” Section 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the field, remove the metal jumper.
Page 24
Chapter 2 RUGGEDCOM RSG2200 Installing Device Installation Guide Figure 6: Terminal Block Wiring 1. Screw-Type Terminal Block 2. Pluggable Terminal Block 3. Jumper 4. Positive/Live (+/L) Terminal 5. Negative/Neutral (-/N) Terminal (-/N) 6. Surge Ground Terminal 7. Chassis Ground Terminal Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
RUGGEDCOM RSG2200 Chapter 2 Installation Guide Installing Device Section 2.5.2 Wiring Examples The following illustrate how to connect power to single and dual power supplies. Figure 8: Single AC Power Supply Figure 9: Single DC Power Supply Wiring Examples...
Page 26
Chapter 2 RUGGEDCOM RSG2200 Installing Device Installation Guide Figure 10: Dual AC Power Supply Figure 11: Dual DC Power Supply Wiring Examples...
Connecting to the Device The following describes the various methods for accessing the ROS console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG2200. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and ROS interfaces. The console port provides access to ROS's console and Web interfaces.
Chapter 3 RUGGEDCOM RSG2200 Device Management Installation Guide Name Description Comment RJ45 Male Female Read to Send Ring Indicator The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected.
The RUGGEDCOM RSG2200 can be equipped with various types of communication ports to enhance its abilities and performance. With five available slots, the RUGGEDCOM RSG2200 supports a variety of one- or two-port fiber or copper Ethernet module of various speeds with up to nine Gigabit Ethernet (1 Gbps) ports.
Section 4.1 Copper Ethernet Ports The RUGGEDCOM RSG2200 supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 male connectors. The RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
RUGGEDCOM RSG2200 Chapter 4 Installation Guide Communication Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi-Directional Pair B+ Reserved (Do BI_DC+ Transmit Data+ Not Connect) or Bi-Directional Pair C+ Reserved (Do BI_DC- Receive Not Connect) Data- or Bi- Directional Pair C-...
The RUGGEDCOM RSG2200 features two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. The following SFP transceivers are compatible with the RUGGEDCOM RSG2200. For more information, including RUGGEDCOM SFP Transceiver Catalog installation/removal instructions and ordering information, refer to the [https://support.industry.siemens.com/cs/ww/en/view/109482309].
To install a GBIC optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
Installation Guide IMPORTANT! Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2200. Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges (ESD). This can be accomplished by wearing an ESD-preventive wrist strap connected to either the chassis ground connector or a bare metal surface on the router/switch.
Page 37
RUGGEDCOM RSG2200 Chapter 4 Installation Guide Communication Ports CAUTION! Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before performing installing or removing components from the device. An electrostatic discharge (ESD) can cause serious damage to the component once it is outside the chassis.
Page 38
Chapter 4 RUGGEDCOM RSG2200 Communication Ports Installation Guide Removing a GBIC Optical Port...
Section 5.8, “Dimension Drawings” Section 5.1 Power Supply Specifications The RUGGEDCOM RSG2200 can be equipped with the following power supplies: CAUTION! Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power input is above or below the specified input range.
NOTE • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
RUGGEDCOM RSG2200 Chapter 5 Installation Guide Technical Specifications Connector RJ45 Speed 1000 Mbps Duplex FDX/HDX Cable Type > CAT-5 Wiring Standard TIA/EIA T568A/B Maximum Distance 100 m (328 ft) Isolation 1.5 kV Auto-Negotiating Shielded or unshielded. Auto-crossover and auto-polarity. Typical distance. Dependent on the number of connectors and splices.
Page 42
9/125 1310 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Gigabit Ethernet (1 Gbps) Optical Specifications NOTE These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20 to 85 °C (-4 to...
Installation Guide Technical Specifications Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. Operating temperature range of -25 to 85 °C (-13 to 185 °F).
RUGGEDCOM RSG2200 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSG2200 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
Installation Guide Certification Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 This device was designed and manufactured using a certified ISO (International Organization for Standardization) quality program that adheres to the following standard: •...
Certification Installation Guide Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RSG2200 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 NOTE • In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise, all Class 1 requirements are met for copper ports.
Page 51
EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RSG2200 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
Page 52
Chapter 6 RUGGEDCOM RSG2200 Certification Installation Guide Description Test Levels 1 kV differential mode @ 1 MHz AC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz HV Impulse Signal Ports 5 kV (Fail-Safe Relay Output) DC Power Ports...