Page 2
Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2200 Communication Ports Technical Specifications Installation Manual Certification 01/2020 C79000-G8976-1043-15...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Preface ............................v Related Documents ......................... v Accessing Documentation ....................... v Training ........................... v Customer Support ........................vi Contacting Siemens ........................ vi Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
Page 5
European Union (EU) ..................39 6.1.3 FCC ........................40 6.1.4 FDA/CDRH ......................40 6.1.5 ISED ........................40 6.1.6 ISO ........................41 6.1.7 RoHS ........................41 6.1.8 Other Approvals ....................41 EMC and Environmental Type Tests ..............41 RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Preface This guide describes the RUGGEDCOM RSG2200. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device. It is also recom- mended for use by network and system planners, system programmers, and line technicians.
Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
Introduction The RUGGEDCOM RSG2200 is a rugged, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically de- manding utility substation, railway and industrial environments. The RUGGEDCOM RSG2200’s superior rugged hardware design coupled with the embedded Rugged...
CSA/UL 60950-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RSG2200 features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The dis- play panel can be located on the rear, front or top of the device, depending on the mounting configuration.
"Connect- ing to the Device (Page 21)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2200: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device.
Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2200 is designed for maximum mounting and display flexibili- ty. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail, or directly on a panel.
2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2200 can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
2.3.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2200 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG2200 can be equipped with panelDIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
Control of the failsafe relay output is configurable through RUGGEDCOM RSG2200 . One common application for this relay is to signal an alarm if a power failure oc- curs. For more information, refer to the RUGGEDCOM RSG2200 User Guide for the RUGGEDCOM RSG2200.
Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2200 supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM RSG2200 can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies . The screw-type ter- minal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
Identify the internal power module (POWER 1 or POWER 2) appropriate for the power supply (AC or DC). Use these screws along with #6 ring lugs to secure the wires to the terminal block. Note For wiring options, refer to "Wiring Examples (Page 16)". RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 22
Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to the chassis ground terminal. The surge ground termi- nals are used as the ground conductor for all surge and transient suppression cir- cuitry internal to the unit. RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Make sure the supplied terminal block cover is always installed before the de- vice is powered. Install the terminal block cover. 2.5.2 Wiring Examples The following illustrate how to connect power to single and dual power supplies. RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 24
Installing the Device 2.5.2 Wiring Examples Figure 2.7 Single AC Power Supply Figure 2.8 Single DC Power Supply RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 25
Installing the Device 2.5.2 Wiring Examples Figure 2.9 Dual AC Power Supply Figure 2.10 Dual DC Power Supply RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 26
Installing the Device 2.5.2 Wiring Examples Figure 2.11 Dual AC/DC Power Supply RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
The following describes the various methods for accessing the RUGGEDCOM RSG2200 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RSG2200 User Guide for the RUGGEDCOM RSG2200. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and RUGGEDCOM RSG2200 interfaces.
Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2200 console and Web interfaces via the device's IP address. For more information about available ports, refer to "Communication Ports (Page 23)".
The exact configuration of the device can be determined by reading the factory data file through the RUGGEDCOM RSG2200 user interface. For more information about how to read the factory data file, refer to the RUGGEDCOM RSG2200 User Guide for the RUGGEDCOM RSG2200.
Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM RSG2200 supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) ca- bles with either RJ45 male connectors. The RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
(Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. Tx Connector Tx Connector Rx Connector Rx Connector Figure 4.5 LC Port Figure 4.4 SC Port Tx Connector Rx Connector Figure 4.6 ST Port RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
The RUGGEDCOM RSG2200 features two Small Form-Factor Pluggable (SFP) trans- ceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. The following SFP transceivers are compatible with the RUGGEDCOM RSG2200. For more information, including installation/removal instructions and ordering infor- RUGGEDCOM SFP Transceiver Catalog [https://support.indus- mation, refer to the try.siemens.com/cs/ww/en/view/109482309]...
NOTICE Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2200. Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges (ESD). This can be accomplished by wearing an ESD-preventive wrist strap connected to either the chassis ground connector or a bare metal surface on the router/switch.
Page 35
Remove the dust cap from the cable and immediately connect it to the port. Connect the cable to a network and observe the LED associated with the port. For more information about the LED, refer to "Communication Ports (Page 23)". RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at the proper temperature (-40 to 85 °C or -40 to 185 °F). Insert a dust plug into the socket opening to prevent the ingress of dust and dirt. RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 37
Communication Ports 4.4.2 Removing a GBIC Optical Port RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2200 can be equipped with the following power supplies: CAUTION Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range.
Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
1310 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Gigabit Ethernet (1 Gbps) Optical Specifications Note These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20 to 85 °C (-4 to 185 °F) operation only.
5.6 Operating Environment Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. GBIC Gigabit (1 Gbps) Transceiver Specifications Note GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless...
Certification The RUGGEDCOM RSG2200 device has been thoroughly tested to guarantee its con- formance with recognized standards and has received approval from recognized reg- ulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RSG2200 complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 16.70068356:...
Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vi)".
Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Page 49
2.5 kV Common Oscillatory DC Power Ports 1 kV Differential Mode @1 MHz AC Power Ports IEC 61000-4-16 Mains Frequen- Signal Ports 30 V Continuous cy Voltage AC and DC 300 V for 1s Power Ports RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 50
EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RSG2200 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications.
Page 51
85 °C (185 °F), 16 Hours IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95% (Non-Condensing), 55 °C (131 °F), 6 Cycles IEC 60068-21-1 Vibration 2g @ 10-150 Hz IEC 60068-21-2 Shock 30 g @ 11 ms RUGGEDCOM RSG2200 Installation Manual, 01/2020, C79000-G8976-1043-15...
Page 52
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...