hit counter script
Siemens RUGGEDCOM RSG2300PF Instruction Manual

Siemens RUGGEDCOM RSG2300PF Instruction Manual

Simatic net

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RSG2300PF
Edition
04/2021
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSG2300PF

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2300PF Edition 04/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2300PF Communication Ports Technical Specifications Installation Manual Certification 04/2021 C79000-G8976-1348-09...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 European Union (EU) ..................39 6.1.3 FCC ........................40 6.1.4 FDA/CDRH ......................40 6.1.5 ISED ........................40 6.1.6 ISO ........................41 6.1.7 RoHS ........................41 6.1.8 Other Approvals ....................41 EMC and Environmental Type Tests ..............41 RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Contacting Siemens • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 10: Introduction

    AC power is not available or where it is cost-prohibitive to provide locally. The RUGGEDCOM RSG2300PF additionally offers 802.3af standard Power over Ethernet (PoE) on up to 4 10/100BaseTx ports. The RUGGEDCOM RSG2300PF is an ideal solution to power and connect several Ethernet devices (such as IP phones, video cameras, and wireless access points) where AC power is not available or cost- prohibitive to provide locally.
  • Page 11: Description

    PoE power supply: 48 VDC Description The RUGGEDCOM RSG2300PF features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 12: Required Tools And Materials

    4 x #8-32 screws For mounting the device to a panel. Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment. RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Supported Fiber Optic Cables

    1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) — 1300 2000 — — OM3 (50/125) 1500 — 1300 2000 — — OM4 (50/125) 3500 — 1300 2000 — — Laser optimized. RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 15 Introduction 1.5.3 Supported Fiber Optic Cables RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2300PF is designed for maximum mounting and display flexibility.
  • Page 18: Mounting The Device To A Rack

    2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2300PF can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 19: Mounting The Device On A Din Rail

    2.3.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2300PF can be equipped with panel/ DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 20: Mounting The Device To A Panel

    2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG2300PF can be equipped with panelDIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 21: Connecting The Failsafe Alarm Relay

    RSG2300PF . One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RSG2300PF. The following shows the proper relay connections. RUGGEDCOM RSG2300PF...
  • Page 22: Connecting Power

    Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2300PF supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RSG2300PF can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power supply and PoE ports.
  • Page 23: Connecting Ac Or Dc Power

    Identify the internal power module (POWER 1 or POWER 2) appropriate for the power supply (AC or DC). Use these screws along with #6 ring lugs to secure the wires to the terminal block. Note For wiring options, refer to "Wiring Examples (Page 18)". RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 24 Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to the chassis ground terminal. The surge ground terminals are used as the ground conductor for all surge and transient suppression circuitry internal to the unit. RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 25: Connecting External Poe Power

    Install the terminal block cover. 2.5.2 Connecting External PoE Power The RUGGEDCOM RSG2300PF supports up to four 10/100Base-TX Power-over- Ethernet (POE) Ports that require power from an external source. Note For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in).
  • Page 26 Jumper Terminal 4 (Chassis Ground) Terminal 5 (+/L) Terminal 7 (-/N) Chassis Ground Terminal Figure 2.7 Terminal Block Wiring Connect the negative wire from the power source to terminal 7 (-/N) on the terminal block. RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 27: Wiring Examples

    Make sure the supplied terminal block cover is always installed before the device is powered. Install the terminal block cover. 2.5.3 Wiring Examples The following illustrate how to connect power to single and dual power supplies. Figure 2.8 DC and 48 VDC PoE Power Supply RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 28 Installing the Device 2.5.3 Wiring Examples Figure 2.9 AC and 48 VDC PoE Power Supply RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 29 Installing the Device 2.5.3 Wiring Examples RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 30: Device Management

    RUGGEDCOM RSG2300PF. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and RUGGEDCOM RSG2300PF interfaces. The console port provides access to RUGGEDCOM RSG2300PF's console and Web interfaces. NOTICE The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting.
  • Page 31: Configuring The Device

    RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2300PF console and Web interfaces via the device's IP address. For more information about available ports, refer to "Communication Ports (Page 23)".
  • Page 32: Communication Ports

    Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2300PF chassis: • Slot 1 supports a two-port fiber or copper module, or an additional two-port 10/100Base-TX 802.3af (PoE) module for extra PoE ports •...
  • Page 33: Copper Ethernet Ports

    Figure 4.2 Port LEDs Copper Ethernet Ports The RUGGEDCOM RSG2300PF supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 male connectors. The RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 34: Poe Ports

    75 W, to prevent exceeding the power budget, port priorities can be set via the RUGGEDCOM RSG2300PF operating system to disable low priority ports when demand is too high. Ports can also be enabled/disabled and placed on a power schedule to conserve power.
  • Page 35: Fiber Optic Ethernet Ports

    (Straight Tip) connectors. Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link.   Tx Connector Tx Connector Rx Connector Rx Connector Figure 4.6 LC Port Figure 4.5 MTRJ Port RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 36: Sfp Transceivers

    "Fiber Optic Ethernet Port Specifications (Page 33)". SFP Transceivers The RUGGEDCOM RSG2300PF supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state.
  • Page 37: Installing A Gbic Optical Port

    To install a GBIC optical port, do the following: NOTICE Electrical hazard – risk of damage to equipment Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 38: Removing A Gbic Optical Port

    Make sure all potential electrostatic build-up has been properly discharged to prevent an electrostatic discharge (ESD). This can be accomplished by wearing an ESD-preventive wrist trap connected to either the chassis ground connector or a bare metal surface on the router/switch. RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 39 Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at the proper temperature (-40 to 85 °C or -40 to 185 °F). Insert a dust plug into the socket opening to prevent the ingress of dust and dirt. RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 40: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2300PF can be equipped with the following power supplies: NOTICE Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range.
  • Page 41: Failsafe Relay Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 42: Fiber Optic Ethernet Port Specifications

    14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
  • Page 43 All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. GBIC Gigabit (1 Gbps) Transceiver Specifications Note GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless...
  • Page 44: Operating Environment

    Technical Specifications 5.7 Operating Environment Operating Environment The RUGGEDCOM RSG2300PF is rated to operate under the following environmental conditions. Ambient Operating -40 to 85°C (-40 to 185 °F) Temperature Ambient Storage -40 to 85°C (-40 to 185 °F) Temperature Ambient Relative...
  • Page 45 Technical Specifications 5.9 Dimension Drawings 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 46 Technical Specifications 5.9 Dimension Drawings 32.77 21.08 11.68 479.29 470.4 461.0 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 47 Technical Specifications 5.9 Dimension Drawings 11.7 10.4 476.3 486.4 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 48: Certification

    UL 62368-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 49: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 50: Iso

    Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 51 DC Power Ports 30% for 0.1 s   and Interrupts 60% for 0.1 s 100% for 0.05 s IEC 60255-5 Dielectric Strength Signal Ports 2 kV (Fail-Safe   Relay Output) DC Power Ports 2 kV   RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 52 EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RSG2300PF meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 53 Humidity (Damp Heat, Cyclic) Test Db 95% (Non-Condensing), 55 °C (131 °F), 6 Cycles IEC 60068-2-6 Vibration 2g @ 10-150 Hz, 2 hours per axis IEC 60255-21-1 IEC 60068-2-27 Shock 30 g @ 11 ms IEC 60255-21-2 RUGGEDCOM RSG2300PF Installation Manual, 04/2021, C79000-G8976-1348-09...
  • Page 54 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Simatic net ruggedcom rsg2300pf

Table of Contents