26. Remove and discard the commutator seal from the
commutator cover (Fig. 62).
27. Remove the eleven hex socket head screws, that
hold the metering package together (Fig. 63). Use a
3/32 in. Allen wrench. Inspect the screws for thread and
socket damage and replace as necessary.
28. Lift the commutator cover from the metering pack-
age (Fig. 64).
29. Inspect the ground surfaces of the commutator cov-
er. You should notice a "normal" polished pattern due to
the rotation of the commutator. If the cover has nicks,
burrs, or scoring, it must be replaced.
Reelmaster 6500–D/6700–D
Page 4 – 75
Figure 62
Figure 63
Figure 64
Hydraulic System