hit counter script

Backlap Switch; Start Relay - Toro Reelmaster 6500–D Service Manual

Hide thumbs Also See for Reelmaster 6500–D:
Table of Contents

Advertisement

Backlap Switch

The Backlap switch is a three–way switch. Test the
switch by disconnecting the wires and connecting a con-
tinuity tester across terminals of switch.
With the switch OFF, the tester should show no continu-
ity across terminals 4 – 5 or 5 – 6.
With the switch in the FRONT position (toward keyway),
tester should show continuity across terminals 4 and 5.
With the switch in the REAR position (away from key-
way), tester should show continuity across terminals 5
and 6.
Terminals on switch
1
2
3
4
5
6

Start Relay

To test the relay, disconnect the relay wire connector
and install a continuity tester between the relay termi-
nals (terminals 30 and 87). The relay should make and
break continuity at terminals 30 and 87 as 12 V.D.C. is
connected and disconnected to terminal 85 with termi-
nal 86 connected to ground.
Reelmaster 6500–D/6700–D
Wire color
(Not used)
(Not used)
(Not used)
Blue
Black
White
Page 5 – 39
1
Figure 23
1. Backlap switch
Figure 24
Electrical System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reelmaster 6700 d

Table of Contents