Chapter 2
Mounting Instructions
Step 7
Loosen the round end of the liquid tight connector by turning counterclockwise, but do not remove (see
Figure
Figure 2-27
1
Thread end
Carefully screw the threaded end of the adapter into the access point and hand-tighten.
Step 8
Use an adjustable wrench, the 22 mm socket, or the Sealcon S-2200-WR wrench to tighten the threaded
Step 9
end of the adapter to 6 to 7 ft lbs ( 8.1 to 9.5 Nm).
Step 10
Carefully remove approximately 1 to 2 ft (30.5 cm) of the external jacket from the fiber-optic cable,
exposing the inner strand.
Step 11
Carefully insert the fiber-optic LC cable connector into the rounded end of the liquid tight adapter (see
Figure
Step 12
Wrap excess fiber-optic cable around the take-up reels in a figure 8 pattern.
Step 13
Insert the fiber-optic LC cable connector into the SFP module.
Step 14
Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs
(3.66 to 4.34 Nm).
Step 15
Close the hinged cover (see the
OL-12632-02
2-27).
Liquid -Tight Adapter
2-27), and push through the adapter.
"Closing the Access Point Hinged Cover" section on page
Cisco Aironet 1520 Series Outdoor Mesh Access Point Hardware Installation Guide
Connecting a Fiber-Optic Cable to the Access Point
2
Round end
2-39).