hit counter script

Cisco RFGW-10 Hardware Installation Manual page 26

Rf gateway 10
Hide thumbs Also See for RFGW-10:
Table of Contents

Advertisement

Cisco RFGW-10 Components
Table 1-3
DC PEM LEDs
LED
48V1
48V2
FAN FAIL
Fault
CUR LIM FAIL
TEMP FAIL
OUTPUT OK
Cisco RF Gateway 10 Hardware Installation Guide
1-12
Status
Green
Red
Blank
Green
Red
Blank
Blank
Red
Blank
Red
Blank
Red
Blank
Red
Green
Red
Chapter 1
Description
Power input is wired correctly and
receiving proper DC power input.
Fault with power input. Typically this
means that the power input is wired
incorrectly with reverse polarity.
Sometimes it also indicates a failure on
the power input.
External power source is not providing
power correctly (typically no power is
provided).
Power input is wired correctly and
receiving proper DC power input.
Fault with power input. Typically this
means that the power input is wired
incorrectly with reverse polarity.
Sometimes it also indicates a failure on
the power input.
External power source is not providing
power correctly (typically no power is
provided).
Normal Operation.
Alarm Condition. Fan operation is not
normal.
Normal Operation.
Alarm Condition. System Fault -
General fault indications. Power supply
is not operating normally.
Normal Operation.
Alarm Condition. System is
experiencing an over current or over
power condition (exceeding 60A on
inputs).
DC PEM is operating within functional
temperature range.
Alarm Condition. DC PEM is
experiencing an over temperature
condition.
All outputs from the PEM to the system
are within normal operating ranges.
Alarm Condition. Indicates that one of
the system voltages from the DC PEM is
out of range.
Overview
OL-16264-04

Advertisement

Table of Contents
loading

Table of Contents