4.2.6

System Version Numbers

Versions of hardware and software
This page shows the versions of the hardware and software with which the IE switch is being
operated:
Figure 4-10
Firmware
The version of the firmware running on the IE switch.
Boot Software
The version of the boot software is displayed here. The boot software is stored permanently
on the IE switch.
FPGA Revision
The FPGA revision used on the IE switch.
Table with entries for the basic device and the modules
The first row of the table indicates the version of the IE switch. The slot column shows the
slot on the basic device. If the information relates to the basic device itself, "-" is entered in
this column. The Hardware column displays the version and the Order Number column the
order number of the IE switch or module.
Syntax of the Command Line Interface
Table 4- 7
Command
info
Table 4- 8
Command
version
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
System Version Numbers
System Version Numbers - CLI>
Description
Along with other information, this command displays the versions of
software with which the IE switch is operated.
System Version Numbers - CLI\SYSTEM>
Description
Displays the firmware, hardware and boot software version of the IE
Switch and provides more detailed information on the basic device and
any modules.
4.2 The System menu
Comment
-
Comment
-