Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Type designations ........................8 Safety instructions ..........................11 Use of approved components ....................11 Important notes on using the SCALANCE X-300 product family ........... 12 Important notes on using the device in hazardous areas ............14 PELV ............................14 Description ............................15 Unpacking and checking ......................
Page 4
Dimension drawing ........................ 61 Certifications and approvals ........................67 X-300 approvals, certificates ....................67 SCALANCE X-300 declaration of conformity ................. 71 X-300 FDA and IEC approvals ....................71 Overview of the X-300 approvals ................... 72 X-300 mechanical stability (in operation) ................72 Index ..............................
Purpose of the Operating Instructions (compact) These operating instructions (compact) contain information with which you will be able to install and connect up a device of the SCALANCE X-300 product line. Validity of these Operating Instructions (compact) These Operating Instructions (compact) are valid for the product group X-300 of the SCALANCE X-300 product line (see product overview).
Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions.
Page 7
1 x 100 Mbps, SC port optical, for glass FO cable (multimode), up to max. 5 km 2 x 100 Mbps, SC ports optical, for glass FO cable (single mode), up to max. 26 km SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
SC port 1000 Mbps single mode FO cable (up to max. 10 km). SC port 1000 Mbps single mode FO cable (up to max. 40 km). SC port 1000 Mbps single mode FO cable (up to max. 70 km). SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 9
The device is also equipped with 2 optical interface transceivers. (Fast Ethernet, long distance interface) • (Fast Ethernet, multimode interface) • Refer to "Transmitter output optical" and "Receiver input" in the technical specifications. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Safety instructions 2.2 Important notes on using the SCALANCE X-300 product family Important notes on using the SCALANCE X-300 product family Safety notices on the use of the device The following safety notices must be adhered to when setting up and operating the device and during all associated work such as installation, connecting up, replacing or opening the device.
Page 13
Safety instructions 2.2 Important notes on using the SCALANCE X-300 product family WARNING Replacing components EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2. WARNING Requirements for the cabinet/enclosure When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
The supply of the devices by PELV (Protective Extra Low Voltage) according to DIN VDE 0100-410 or IEC 60364-4-41 is permitted when the generated nominal voltage does not exceed the voltage limits 25 VAC or 60 VDC. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
1. Make sure that the package is complete. 2. Check all the parts for transport damage. Components of the product The following components are supplied with a SCALANCE X-300: ● Device with C-PLUG exchangeable medium. ● A four-pin terminal block for the 24 VDC power supply.
The SCALANCE X304-2FE provides the following options for the connection of end devices or other network segments: ● 4 RJ-45 jacks ● 2 FO ports (for multimode fiber) Image 3-1 X304-2FE Column Port number Connection type Optical: Fast Ethernet Electrical: Fast Ethernet SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
● 6 RJ-45 jacks ● 1 FO port (for single mode fiber) Image 3-2 SCALANCE X306-1LD FE Column Port number P1 *) Connection type Electrical: Fast Ethernet Electrical: Fast Ethernet *) Optical: Fast Ethernet SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The SCALANCE X307-3 provides the following options for the connection of end devices or other network segments: ● 7 RJ-45 jacks ● 3 FO ports (for multimode fiber) Image 3-3 SCALANCE X307-3 Column Port number Connection Electrical: Fast Ethernet Optical: Gigabit Ethernet type SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The SCALANCE X306-3LD provides the following options for the connection of end devices or other network segments: ● 7 RJ-45 jacks ● 3 FO ports (for single mode fiber) Image 3-4 SCALANCE X307-3LD Column Port number Connection Electrical: Fast Ethernet Optical: Gigabit Ethernet type SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The SCALANCE X308-2 provides the following options for the connection of end devices or other network segments: ● 8 RJ-45 jacks ● 2 FO ports (for multimode fiber) Image 3-5 SCALANCE X308-2 Column Port number Connection Electrical: Fast Ethernet Electrical: Optical: type Gigabit Ethernet Gigabit Ethernet SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The SCALANCE X310 provides the following options for the connection of end devices or other network segments: ● 10 RJ-45 jacks Image 3-9 SCALANCE X310 Column Port number Connection Electrical: Fast Ethernet Electrical: Gigabit Ethernet type SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The SCALANCE X310FE provides the following options for the connection of end devices or other network segments: ● 10 RJ-45 jacks Image 3-10 SCALANCE X310FE Column Port number Connection Electrical: Fast Ethernet type SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The SCALANCE X320-1 FE provides the following options for the connection of end devices or other network segments: ● 20 RJ-45 jacks ● 1 FO port (for multimode fiber) Image 3-11 SCALANCE X320-1 FE Column Port number Connection Electrical: Fast Ethernet Optical: type Fast Ether- SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
3. The result of the action depends on the initial situation: – If the redundancy manager and media redundancy were disabled, media redundancy is also enabled after enabling the redundancy manager. – If you disable the redundancy manager, media redundancy remains enabled. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Bad firmware image. During normal operation, the "F" LED provides the following information: LED color LED status Meaning during operation No operating problems. The device has detected an error. The signaling contact opens. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 30
For devices with power supply unit 24 to 48 VDC: Limit voltage = 17 VDC • For devices with a multiple range power supply unit 100 to 240 VAC / 60 to 250 VDC: • Limit voltage = 46.5 VDC or 80 VAC SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 31
4 times per sec- Port exists and is in the "monitor port" status. In this sta- tus, the data traffic of another port is mirrored to this port. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
LED status Meaning yellow flashes / lit Receiving data at port. With SCALANCE X-300 devices, both the receipt and the sending of data is indicated for the optical gigabit ports. Meaning in display mode B LED color LED status Meaning Port operating at 10 Mbps.
(LEDs, Web-based management, SNMP, CLI and PROFINET diagnostics). 3.6.2 Removing and inserting the C-PLUG (compact housing) NOTICE A C-PLUG may only be removed or inserted when the device is turned off. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 34
3. The housing of the C-PLUG has a protruding ridge on the long side (position B). The slot has a groove at this position. Insert the C-PLUG correctly oriented into the slot. 4. Close the housing again with the sealing screw. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The device may only be operated in an environment with pollution degree 1 or 2 (see IEC 60664-1). WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
80 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 50 °C to 70 °C, only use cables with a permitted operating temperature of at least 80 °C. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
When installing and operating the device, keep to the installation instructions and safety- related notices as described in this document and in the manual SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
3. Fit the connectors for the signaling contact. 4. Insert the terminal blocks into the sockets on the IE Switch X-300. Image 4-1 Mounting an IE Switch X-300 on a DIN rail (35 mm) SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Removing an IE Switch X-300 from a DIN rail (35 mm) Removing an IE Switch X-300 1. Push the X-300 down. 2. Swing the device upwards. No tools are necessary for removing the device. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
To remove an IE Switch X-300 from the SIMATIC S7-300 standard rail: 1. First disconnect all connected cables. 2. Loosen the screws on the underside of the S7 standard rail and lift the IE Switch X-300 away from the rail. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The wall mounting must be capable of supporting at least four times the weight of the IE Switch X-300. Note For wall mounting of a rack device (R), use suitable fittings and mount the device as shown in the drawing. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 44
The ring ports of the device being inserted in the ring were configured as ring ports. The required redundancy mode must also be enabled (see "Configuration Manual SCALANCE X-300 / X-400", section "X-300 Ring Configuration"). If the device is intended to operate as the redundancy manager, "Redundancy manager enabled" must also be set.
3. Connect the signaling contact of the switch according to the following description. 4. Connect the power supply of the switch according to the following description. 5. Connect the network nodes / subnets to the switch. 6. Turn on the power supply for the switch. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
● 100 to 240 VAC variant: Grounding is via the mounting bracket on the device or alternatively/additionally via the screw-on bolts on the rear of the device. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The signaling contact can be subjected to a maximum load of 100 mA (safety extra low voltage SELV 12 VDC / 24 VDC). Table 5- 1 Pin assignment of the signaling contact Pin number Assignment (example) Pin 1 Pin 2 SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
• The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV), 24 V DC). • Never operate the device with AC voltage or DC voltage higher than 32 V DC. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 49
The two power inputs are non-floating. Table 5- 3 Pin assignment for the power supply Pin number Assignment (terminal block) Pin 1 L1+ (24 VDC) Pin 2 Pin 3 Pin 4 L2+ (24 VDC) SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
700 g IP30 X306-1LD FE X307-3, 120 × 125 × 123 mm 1400 g IP30 X307-3LD, X308-2, X308-2LD, X308-2LH, X308-2LH+, X310, X310FE, X320-1FE, 180 × 125 × 123 mm 1650 g IP30 X320-3LD FE SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 52
Max. 55 ℃ as of 2000 m X308-2LD, version 1: densation) Max. 50 ℃ as of 3000 m X308-2LH, 0 °C to +60 °C X308-2LH+, As of hardware product X310, version 2: X310FE -40 ℃ to +60 °C SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
X320-3LD FE 20 x RJ-45 jacks with MDI-X assignment 1 x SC duplex socket (MM) 10/100 Mbps (half / full duplex) 2 x SC duplex sockets (SM) (100 Mbps, full duplex to 100BaseFX) SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 54
1 x 2-pin Table 6- 9 Electrical data: Transmitter output (optical) and receiver input Device variant Transmitter output (optical) Receiver input min. [dBm] max. [dBm] Sensitivity min. [dBm] Input power max. [dBm] X304-2FE X306-1LD FE SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 55
The device is also equipped with 2 optical interface transceivers. Fast Ethernet, long distance interface • Fast Ethernet, multimode interface • As a result, the electrical data in the technical specifications is divided into two parts: transmitter output optical and receiver input. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
X306-1LD FE 9/125 µm 0 to 26 km ≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5 single mode fiber dB; 14 dB max. permitted FO cable attenuation at 2 dB link power margin SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
2 dB link power margin; minimum cable attenua- tion 8 dB X310 Other properties Table 6- 14 Switching properties Max. number of learnable addresses 8000 Aging time 30 sec Switching technique Store and forward Latency 5 μs SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Note The IE Switches X-300 are available in small, medium and large variants. The dimension drawings are shown below. Small design Image 7-1 Small design dimension drawing (example used here SCALANCE X306-1LD FE) SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 65
7.1 Dimension drawing Large design Image 7-5 Large design dimension drawing Part 1 (example used here SCALANCE X320-3LD FE) Image 7-6 Large design dimension drawing Part 2 (example used here SCALANCE X320-3LD FE) SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 68
(http://support.automation.siemens.com/WW/view/en/27069465)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
Page 69
Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
Page 70
● UL 60950-1 (Information Technology Equipment) ● ANSI/ISA 12.12.01-2007 ● CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
SCALANCE X-300 declaration of conformity (https://support.industry.siemens.com/cs/ww/en/ps/15296/cert) 1. Click on the entry "SCALANCE X-300 managed" in the navigation panel at the top edge of the window and from the drop-down list that opens, select the entry for your product group.
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate. Note Shipbuilding approval No applications for shipbuilding approvals will be made for the SCALANCE X-300. X-300 mechanical stability (in operation) Type IEC 60068-2-6 vibration IEC 60068-2-27 shock 5 –...
Page 73
IEC 60068-2-27 shock 5 – 9 Hz: 3.5 mm 15 g, 11 ms duration 9 – 150 Hz: 1 g 6 shocks per axis 1 octave/min, 20 sweeps X320-1FE ● ● X320-3LD FE ● ● SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...
Page 74
Certifications and approvals 8.5 X-300 mechanical stability (in operation) SCALANCE X-300 Compact Operating Instructions, 05/2016, A5E00982643-14...