hit counter script

Fc 5074, Fc 5079 - Control Panel - Nb1 - IBM i 830 Repair Manual

Table of Contents

Advertisement

Remove and Replace Procedures
5. Are you finished with the repair?
6. To Install a disk unit using dedicated maintenance perform the following:
FC 5074, FC 5079 – Control Panel – NB1
Attention: The control panel is sensitive to electrostatic discharge (see
"Appendix C. Working with Electrostatic Discharge-Sensitive Parts" on page 955).
1. Power off the expansion tower. (See "Powering On and Powering Off the
2. Disconnect the AC power cord from the expansion tower.
3. Open the front cover. (See "FC 5074, FC 5079, FC 9079 – Covers" on page 623.)
4. Pull on the two side fasteners to release the control panel assembly.
630
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
No
Yes
Replace the covers that were removed during this procedure and return
to the procedure that sent you here.
This ends the procedure.
a. Power off the system (see "Powering On and Powering Off the System and
Logical Partitions" on page 922).
b. Disconnect the power cord.
c. Put the disk unit part way into the desired slot and rotate the handle of the
disk unit towards you.
d. Push the disk unit completely into the slot and rotate the handle towards
the disk unit to latch it into the slot.
e. Replace the covers that were removed during this procedure and return to
the procedure that sent you here.
This ends the procedure.
System and Logical Partitions" on page 922.)

Hide quick links: