Table 12. Loop Number to NIC Port Location Labels for Models 830/SB2 and 840/SB3 (continued)
Decimal Loop Number
259
260
261
262
263
On models 830/SB2 follow this reference to Figure 32 on page 716.
On models 840/SB3 follow this reference to Figure 39 on page 732.
BUS-PIP1
You will perform BUS-PIP1 on an SPD Migrated Tower. Go to "BUS-PIPs for
Migrated Towers" on page 287.
This ends the procedure.
BUS-PIP2
You will perform BUS-PIP2 on an SPD Migrated Tower. Go to "BUS-PIPs for
Migrated Towers" on page 287.
This ends the procedure.
BUS-PIP3
You will perform BUS-PIP3 on an SPD Migrated Tower. Go to "BUS-PIPs for
Migrated Towers" on page 287.
This ends the procedure.
BUS-PIP5
This procedure will attempt to identify a failing I/O adapter card controlled by the
IOP processor which you are performing isolation on.
1. Do you have a frame ID from the Service Action Log (SAL)?
2. Is the frame that you are working on a FC 5033, 5034, 5035, 5076 or 5077?
3. The I/O processor is in a system unit or I/O tower other than an SPD
4. Do you have a Direct Select Address (DSA)?
Hexadecimal Loop
Number
0103
0104
0105
0106
0107
Yes
No
↓
Go to step 4 of this procedure.
No
Yes
↓
Go to step 6 on page 286 of this procedure.
Migrated Tower. Perform "BUS PIP IOP-02, Isolate to Failing I/O Adapter
Resource" on page 309. If BUS PIP IOP-02 directs you to return to this
procedure then return to the procedure which sent you here.
This ends the procedure.
Yes
No
↓
Obtain the bus number by performing one of the following steps:
a. Record the Direct Select Address (DSA) which is word 7 from the
SAL display. The bus number is the 4-leftmost characters.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Bus, High-Speed Link (HSL) PIPs
System Model
830 / SB2, 840 / SB3
840 / SB3
840 / SB3
840 / SB3
840 / SB3
HSL Port Labels on System
Unit or Processor Tower
"D0" and "D1"
"E0" and "E1"
"F0" and "F1"
"G0" and "G1"
"H0" and "H1"
285