UJE34

The error message may have been logged from a temporary error that is not
caused by equipment failure. This type of error message sometimes contains
information about system performance.
See the original system message for cause and recovery information about the
error.

UJE35

The configuration parameter that was identified as a possible problem can be
verified by displaying the local area network line description with the DSPLIND
command.
The line description was created by the CRTLINTRN, the CRTLINETH or the
CRTLINDDI command. You may need to review the appropriate command
information to determine if the configuration parameter is wrong.
For more information about commands related to communications, see the
Programming: Control Language and the Communications Configurations
reference topics in the iSeries 400 Information Center, which is available at
http://www.ibm.com/eserver/iseries/infocenter
Some software problems can be temporarily solved by changing the configuration
parameter, even if the original value was correct. Report this problem to your
service representative if you use this temporary change.
This ends the procedure.

UJE40

The problem may be at the remote site or on the network media.
Perform the following:
1. Ask the remote site operator to verify the following:
v The remote equipment is powered on and ready.
v The configuration values are correct.
v The local area network cables are securely connected and are not damaged.
2. If the problem continues, run all available diagnostic tests on the remote
equipment and perform the repair action specified.
This ends the procedure.

ULNZ3

Communications line problems:
When a workstation is attached to the system through modems, it may fail or lose
communication with the system for various lengths of time. This is due to a
communications line problem.
Refer to the modem service information to determine how to test the modems and
verify that the communications line between the modems is working correctly.
This ends the procedure.