Commissioning
When the hob has been fully installed it will be necessary to check
the minimum flame setting. To do this, follow the procedure below.
-
Turn the gas tap to the MAX position and ignite.
-
Set the gas tap to the MIN flame position then turn the control
knob from MIN to MAX several times. If the flame is unstable or
is extinguished follow the procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Remove the control knob.
To adjust, use a thin bladed
screwdriver and turn the
adjustment screw (see diagram)
until the flame is steady and does
not extinguish, when the knob is
turned from MIN to MAX. Repeat
this procedure for all burners.
Pressure Testing
Remove left hand pan support and front left burner cap
and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite another burner.
The pressure reading should be nominally 20mbar and
must be between 17 mbar and 25 mbar.
Turn off the burner supplies.
22
minimum adjustment screw