Important Safety Information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350350 Installation This appliance must be installed and serviced by a competent person as stated in the Gas Safety ( Installation and Use) Regulations Current Editions and the IEE Wiring Regulations.
Page 3
Do not use this hob if it is in contact with water. Do not operate the hob with wet hands. Ensure the control knobs are in the ‘OFF’ position when not in use. When using other electrical appliances, ensure the cable does not come into contact with the hot surfaces of the cooking appliance.
Contents Instructions for the User Important Safety Information Description of the Hob Operation Maintenance and Cleaning Something Not Working? Service and Spare Parts Customer Care Guarantee Conditions Instructions for the Installer Engineers technical data Important safety requirements Installation Electrical connections Wiring diagram Fault Finding Commissioning...
Description of the Hob 1. Hob Top 2. Semi-rapid burner 3. Auxiliary burner 4. Rapid burner 5. Ultra-rapid burner (triple crown) 6. Control knobs Installation Any gas installation must be carried out by a registered competent person, and in accordance with existing rules and regulations. The relevant instructions are to be found in the second section of this manual.
Operation Hob burners control knobs The symbols on the knobs mean that : there is no gas supply there is maximum gas supply there is minimum gas supply Lighting the burners For easier lighting, proceed before putting a pan on the pan support. To light a burner: turn the relevant knob anticlockwise to maximum position A - Burner cap...
Using the Wok Stand Fig. 2 A wok stand is provided to enable you to use a round bottomed wok on the hob. The wok stand must only be used on the central burner, and should not be used with any other type of wok or pan. When fitting the wok stand, ensure the recesses in the frame fit securely onto the bars of the pan supports, as shown in figure 2.
Something Not Working? If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre. SYMPTOM SOLUTION There is no spark when lighting the gas Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped (if fitted) Check the mains fuse has not blown...
For general enquiries concerning your AEG-Electrolux appliance and for further information on AEG-Electrolux products, contact our Customer Care Department by letter or telephone at the address below or visit our website at www.aeg.co.uk For Customer Services in the Republic of...
Standard guarantee conditions We, AEG-Electrolux, undertake that if within 12 months of the date of the purchase this AEG-Electrolux appli- ance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, we will, at our discretion repair or replace the same FREE OF CHARGE for labour, materials or carriage on condition that: ·...
Instruction for the Installer Engineers technical data Burner Dia. Tap By-pass Overall dimensions 1/100 mm Width: 680 mm Auxiliary Depth: 510 mm Semi-rapid Cut out dimensions Rapid Ultra-rapid Width: 560 mm Depth: 480 mm Aeration adjustment none Supply Connections Heat Input Gas:R 1/2 inch (1/2 inch male) Rear right hand Ultra-rapid Burner 4.0 kW (13652 BTU/HR) corner...
Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations.
Installation Important This hob must be installed by a competent person to the relevant Gas Standards. Any gas installation must be carried out by a registered competent person. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.
Cut Out Size The dimensions of the cut-out are given in the diagram. FO 2038 Building In Building over a cupboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface.
FO 2564 FO 2563 Building over a kitchen unit with door Proper arrangements must be taken in designing the furniture unit, in order to avoid any contact with the bottom of the hob which can be heated when it is operated. The recommended solution is shown in diagram The panel fitted under the hob ("a") should be easily removable to allow easy access if...
Fitting the Hob into the worktop Carry out the building in of the hob as follows: • put the seals supplied with the hob, on the edges of the cut out: place them exactly on the front edge, at 10 mm from the rear edge and at 50 mm from the side edges, as shown in the diagram,...
Electrical connections Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations. THIS HOB MUST BE EARTHED. The manufacturer declines any liability should these safety measures not be observed. This hob is designed to be connected to a 230 V 50 Hz AC electrical supply.
Permanent Connection In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.
Fault Finding Blue Brown Green Yellow Preliminary Electrical Systems Check START Blue Isolate appliance and carry out: Green Brown Yellow A: Earth Continuity check. Carry out: Carry out: D: Resistance to C: Polarity check. Earth check. Has inlet fuse blown? Electricity supply should now be satisfactory.
Page 20
A. EARTH CONTINUITY CHECK Appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary. — Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 Ω (Ohm), check all earth wires for continuity and all contacts are clean and tight.
Page 21
Ignition System / Gas Ignition Check gas supply at Ignitor does not spark burner Check plug top fuse and Light burner manually replace if necessary Check by pass simmer Check polarity and earth adjusted continuity of supply point Check fitting of Check position of the Check earth continuity burners...
Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. Turn the gas tap to the MAX position and ignite. Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times.
Conversion from Natural Gas to LPG IMPORTANT The replacement/conversion from natural gas to LPG should only be undertaken by a competent person. It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted.