Building In - AEG 79902 Operating Instructions Manual

Electronic gas hob
Table of Contents

Advertisement

Building In

A = Auxiliary burner
S R = Semirapid burner
R = Rapid burner
Fig. 1
The hob is designed to be inserted in modular
kitchen units with depth of 550 - 600 mm and
having proper characteristics.
The building-in is also possible in modular units
with a 600 mm width: in this case, the cut-out
in the work top must be carried out as shown in
Fig. 2.
The worktop must be at least 30 mm thick.
If the worktop is thicker than 50 mm, it is
possible to install the hob on modular units of
any width.
Any unit (furniture unit, household appliance,
etc..) placed near the unit which the hob is built
in, shall not exceed the worktop height.
A minimum clearance of 100 mm
between the cut-out in the worktop
and any side wall exceeding the
worktop height must be observed.
The hob dimensions and the cut-out
dimensions are given in fig. 1 and 2.
S R
S R
A
A) Worktop
B) Removable Panel
Dimensions are given
in millimetres
R
Fig. 2
37