After 60 seconds, you can remove the safety
device on the burner by touching both the
Increasing Controls
Control
at the same time.
Then, follow the instructions given in the
paragraph "How to light a burner".
Caution! Check that the burner cap and
crown are correctly positioned (see
diagram).
If the ignition problem persists, refer to
chapter "Something not working".
Never use a manual spark gas-lighter if
the burner ignition device does not work
correctly. If necessary, use a match.
In case of
extinguishing (automatic
reignition)
If the burner flame is accidentally extinguished
(draughts, spilling of liquids, etc.), the gas flow is
immediately interrupted.
After about 20 seconds, the ignition device
automatically repeats the ignition procedure.
Upon reignition, the burner flame is first set at
maximum level, then it is automatically adjusted
to the level set before it was accidentally
extinguished.
If three consecutive reignition attempts fail, a
safety device is set on the burner. The flame
level indicators and the residual heat indicator
flash.
Caution! When the safety device is set
on a burner, the burner controls cannot
be operated for about 60 seconds.
After 60 seconds, you can remove the safety
device on the burner by touching both the
Increasing Controls
Control
at the same time.
Then, follow the instructions given in the
paragraph "How to light a burner".
10
and the Decreasing
accidental
and the Decreasing
Burner
Cap
Burner
crown
Spark
plug
Thermo-