Chapter 10 Troubleshooting

Electrical Section

Cautions
• Be sure to turn off the power of the machine and unplug the power cord before checking cable
connections.
• When you check connection of the cables as instructed in this manual, also check connection and
continuity between connectors.
• Carry out items described in the "Measures" section in order of appearance.
• Some checks and replacement works can be conducted only by repair people. In such cases,
contact your dealer.
Symptom
The machine does not operate even
if the power is turned on.
The machine does not operate even
if the power is turned on.
The message, "Release stop SW to
operate!", is displayed on the panel.
An overtravel error occurs.
The needle stop position error oc-
curs.
142
• Is the power cord of the machine plugged in?
Plug in the power cord.
• Is the connector in the control box connected?
Connect it after checking the types and colors of the connectors.
• Is fuse F1 or F5 on the power PCB in the control box blown?
Replace the fuse with a new one. If the fuse is blown again,
something is faulty. Check to see if the wiring is correct. Replace
the control box with a new one.
• Is the stop switch (Option) turned on?
Reset the stop switch.
• Is the frame within the cap frame area?
Move the frame within the cap frame area and turn on the power.
• Check to see if the signal of the X area sensor turns ON and OFF in
PORT test mode.
When the signal does not change, refer to the block diagram showing
the cable connections and check to see if connection from the X cap
sensor to the main PCB is proper. Replace the X cap sensor with a
new one.
• Is the pulley manually turned and out of the stop angle?
Turn the pulley, adjust the needle at the stop position, and reset the
error.
• Check the signal of the stop position sensor in the encoder test mode.
Refer to the adjustment or cable connection block diagram and
check connection from the needle position detention sensor to the main
PCB. Replace the needle position detection sensor with a new one.
• Is the main shaft brake solenoid operating?
If not, refer to the block diagram showing the cable connections and
check to see if the connections from the brake solenoid to the power
PCB and from connector P27 of the power PCB to connector P1 of the
main PCB are proper.
BES-116AC
Measures