Code
Error Messages
E-2C
Area over
E-2D
Area over
E-2E
Area over
E-2F
Area over
E-31
Area over
E-32
Area over
E-33
Area over
E-34
Area over
E-36
Area over
E-38
Area over
E-39
Area over
E-3C
Area over
This function is not supported.
E-41
Turn off the power
E-42
ERROR 42
E-43
Slave I/F EEPROM read error
E-A1
Main(Z) motor lock
E-A5
ERROR A5
E-A6
ERROR A6
E-A7
ERROR A7
E-A8
ERROR A8
E-A9
Spindle CPU parameter error
E-C1
ERROR C1
E-C3
ERROR C3
E-C9
Embroidering start error
E-CA
ERROR CA
E-CB
Spindle rotation speed error
E-CD
ERROR CD
E-E3
Exhaust fan motor stop
E-E5
ERROR E5
E-E6
ERROR E6
Error
Hoop overhang(-X, -Y)
Hoop overhang(+X, -X, -Y)
Hoop overhang(-X, +Y, -Y)
Hoop overhang(+X, -X, +Y, -Y)
Needle overhang(+X)
Needle overhang(+Y)
Needle overhang(+X, +Y)
Needle overhang(-X)
Needle overhang(-X, +Y)
Needle overhang(-Y)
Needle overhang(+X, -Y)
Needle overhang(-X, -Y)
Invalid start-up error
XY movement error
Slave I/F EEPROM read error
Spindle motor lock
Spindle motor CPU error
Main shaft motor CPU communication com-
mand error
Main shaft motor CPU send/receive error
Main shaft stop position signal error
Spindle CPU parameter error
Area over during embroidering
Embroidering data buffer empty
Embroidering start error
No sewing permisson
Spindle rotation speed error
Speed command can not be received.
Cooling fan motor stop.
Over-run error during interfacing to main PCB
CPU
Framing error during interfacing to main PCB
CPU
BES-116AC
Chapter 9 Error code list
Measures
Pattern or the needle position is out of the embroidering area.
Reset the embroidering area on the panel or move the hoop to
the sewable position.
Turn the power off and on once.
Press the
.
STOP
Turn the power off and on once. If the same error occurs
again, the main PC is faulty.
Press the
. If it occurs frequently, the main shaft mecha-
STOP
nism is faulty.
This is not usually displayed.
Adjust the pulley stop position (100 degrees) above the needle
and press the
. If the error occurs frequently, the parts
STOP
related to the main shaft stop position sensor are faulty.
This is not usually displayed.
Set the embroidering area again on the panel.
This is not usually displayed.
Press the
to cancel the error and press the
STOP
error occurs again, there is a possibility that the spindle is over-
loaded.
Turn the power off and on once. If the same error occurs
again, the main PCB is faulty.
Turn off the power and check the fan harness. Turn on the
power again. If the same error occurs again, the fan or the
main PCB is faulty.
This is not usually displayed.
. If the same
137