hit counter script
HP D7171A - NetServer - LPr Configuration Manual
HP D7171A - NetServer - LPr Configuration Manual

HP D7171A - NetServer - LPr Configuration Manual

Microsoft cluster installation documentation
Hide thumbs Also See for D7171A - NetServer - LPr:

Advertisement

Microsoft Cluster Installation
To assist you in installing your HP NetServer Microsoft Cluster, this file contains three
separate documents combined into one pdf file.
Configuration Guide - This guide provides configuration information specific to your
cluster configuration that you will need during the installation of your cluster.
HP NetServer Microsoft Cluster Installation Guide - Use this document to install
the cluster.
Documentation
18 November 1998
(See next page)

Advertisement

Table of Contents
loading

Summary of Contents for HP D7171A - NetServer - LPr

  • Page 1 Microsoft Cluster Installation Documentation To assist you in installing your HP NetServer Microsoft Cluster, this file contains three separate documents combined into one pdf file. Configuration Guide - This guide provides configuration information specific to your cluster configuration that you will need during the installation of your cluster. HP NetServer Microsoft Cluster Installation Guide - Use this document to install the cluster.
  • Page 2 Version History 18 November 1998 Revised the Configuration Guide to add, “6 maximum per NetRAID adapter” to Logical Disks in Shared Storage. 15 September 1998 Revised the Configuration Guide to add, “Logical Disks – 1 per RAID array” to Shared Storage. 10 June 1998 Package released...
  • Page 3 These configurations minimize single points of failure, provide maximum availability, and have been certified by Hewlett-Packard and Microsoft. This guide is prescriptive; it describes the HP NetServer LH Pro configurations supported by HP. Any configuration not expressly allowed by this guide will not be supported by HP.
  • Page 4 Model HP NetServer LH Pro 6/200 Model 1 Clock speed 200 MHz No. of CPUs 2 (at least two are required) BIOS version 4.05.14 PF or later CPU cache Any size 128 MB minimum. Must be HP. No. of power supplies Hot swap cages May use for local storage;...
  • Page 5 Cabinet Model HP Storage System/6 D3604B No. of cabinets 1, 2 A cluster with a single storage cabinet has only one SCSI bus connected to HP NetRAID channel 0. A cluster with 2 storage cabinets must have one cabinet connected to NetRAID channel 0 and the other cabinet connected to NetRAID channel 1.
  • Page 6 This page intentionally left blank.
  • Page 7 HP NetServer LH Pro Microsoft Cluster Installation Guide 1 October 1997...
  • Page 8 The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 9: Table Of Contents

    Table of Contents Overview of an HP NetServer LH Pro Cluster Installation..........1 Part 1: Installing Additional Hardware Components ............5 Part 2: Setting Up the HP Storage System/6 ..............9 Part 3: Configuring the HP NetRAID Adapter..............12 Part 4: Installing Microsoft Windows NT and Configuring the LAN Adapters ....14 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays .....
  • Page 10: Overview Of An Hp Netserver Lh Pro Cluster Installation

    Installation NOTE Hewlett-Packard does not support nor recommend the installation of clustered HP NetServer systems using Microsoft Cluster Server software unless installed by an HP Cluster Certified Installer. An HP NetServer LH Pro cluster provides a reliable low-cost, increased-availability solution for critical applications.
  • Page 11 Overview of an HP NetServer LH Pro Cluster Installation Unless otherwise specified, when more than one component is required, the additional component(s) must be identical in manufacture and configuration. Hardware The following hardware components are required for HP NetServer LH Pro cluster installations. Quantity Quantity System A...
  • Page 12 Overview of an HP NetServer LH Pro Cluster Installation Software To set up an HP NetServer LH Pro running Microsoft Cluster Server, use the Microsoft Windows NT Server (Enterprise Edition), version 4.0, which includes the following: Windows NT, version 4.0 Windows NT Service Pack 3 Microsoft Cluster Server installation software The following HP software products are also required:...
  • Page 13: Setup Procedure

    Overview of an HP NetServer LH Pro Cluster Installation Setup Procedure You begin a cluster installation by setting up the hardware at both HP NetServer LH Pros, referred to here as System A and System B. The installation is complete when you have setup and tested the Microsoft Cluster Server software on both systems.
  • Page 14: Part 1: Installing Additional Hardware Components

    Part 1: Installing Additional Hardware Components When HP NetServer LH Pros are shipped from the factory, they are configured for stand-alone operation. The first step in creating a cluster is to reconfigure the two HP NetServers for use in a cluster. Because these steps involve opening the HP NetServers, HP recommends you use a Portable Field Service Grounding Kit (3M part number 8505, or equivalent).
  • Page 15 Part 1: Installing Additional Hardware Components Installing Peripheral Components In this step, you will install peripheral components that are necessary for the servers to operate in a cluster configuration. NOTE The standard HP NetServer LH Pro is equipped with 32 to 64 MB of memory. Cluster operations require a minimum of 128 MB of memory.
  • Page 16 Part 1: Installing Additional Hardware Components Connect the free end of the C11 cable from the CD-ROM drive to the 50- pin output connector on the top hot swap cage. The output connector is on the left when the cage is viewed from the back. Remove the C23 cable from the SCSI B controller connector and coil the cable up out of the way.
  • Page 17 Part 1: Installing Additional Hardware Components The connector is keyed to insure correct connection. When connected, the battery backup module protects the HP NetRAID Adapter’s cache memory. HP NetRAID Adapter with Connected Battery Pack NOTE To assemble a certified Microsoft Cluster Server, use only an HP NetRAID Adapter (model number D4943A).
  • Page 18: Part 2: Setting Up The Hp Storage System/6

    Part 2: Setting Up the HP Storage System/6 In this section, you prepare the HP Storage System/6 for cluster operations by: Configuring the internal cabling on the HP Storage System/6 Assigning SCSI IDs (via dip switches) for the disks in the HP Storage System/6 Verifying SS6 Internal Cabling Before connecting the disks housed in the HP Storage System/6, you need to setup the Storage System/6’s internal cables to support the cluster.
  • Page 19 Part 2: Setting Up the HP Storage System/6 Swing the door open, as shown in Step 2. Lift the door off the chassis. Repeat Steps 1-5 for each Storage System/6 to be included in the cluster. HP Storage System/6 Internal Cabling Using the schematic view of the HP Storage System/6’s internal cabling shown below, you need to check and, if necessary re-route, the three cables located inside the storage unit.
  • Page 20 Part 2: Setting Up the HP Storage System/6 Assigning SCSI IDs To configure the shared disks, you need to change the SCSI ID assignments for each of the HP Storage System/6 units you are including in the cluster: Check, and if necessary re-assign, SCSI ID’s for both the upper and lower cages. Configure the DIP switches as indicated in the figure below.
  • Page 21: Part 3: Configuring The Hp Netraid Adapter

    Part 3: Configuring the HP NetRAID Adapter In Parts 1 and 2, you installed additional hardware in your HP NetServers to support cluster operations, and configured both the HP NetServers and the shared storage units for use in the cluster. In Part 3, you will be configuring the HP NetRAID Adapters you installed in Systems A and B using the HP NetRAID Express Tool.
  • Page 22 Part 3: Configuring the HP NetRAID Adapter If the previous step did not force a reboot, continue pressing Escape to exit the NetRAID Express Tools utility. When prompted to exit, press Yes. The utility re-boots to enable the changes you have made. When the HP NetRAID Adapters on both systems are configured, proceed to "Part 4: Installing Microsoft Windows NT, and configuring the LAN Adapters."...
  • Page 23: Part 4: Installing Microsoft Windows Nt And Configuring The Lan Adapters

    Part 4: Installing Microsoft Windows NT and Configuring the LAN Adapters After you have configured the HP NetRAID Adapter, you are ready to install Microsoft Windows NT Server, Enterprise Edition. Prior to Windows NT installation, use the HP EISA Configuration Utility to configure the hardware for use with the network operating system.
  • Page 24 Part 4: Installing Microsoft Windows NT and Configuring the LAN Adapters Installing Microsoft Windows NT In addition to installing Microsoft Windows NT, in this section you also configure the operating system for cluster operations. To install Microsoft Windows NT for Microsoft Cluster Server operations, at both Systems A and B: Insert the Base CD of the Microsoft Windows NT Server, Enterprise Edition and reboot the system.
  • Page 25: Part 5: Installing Hp Netraid Software And Configuring The Disk Arrays

    Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays After Windows NT has been installed and configured for cluster operations and you have upgraded the operating system with Service Pack 3, you need perform the following tasks to prepare Systems A and B for the Microsoft Cluster Server software: Install the NT NetRAID driver Install NetRAID Assistant software...
  • Page 26 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays Connecting the Cluster’s Shared Storage Refer to one of the following schematics as you connect the HP Storage System/6 cabinet(s) to the cluster’s NetServers. Use only D5957A NetRAID Cluster Adapters to connect the HP Storage System/6 to the servers. To connect the HP Storage System/6 unit(s) to the HP NetServers: Power down all cluster hardware including both HP NetServers and the HP Storage System/6 cabinet(s) Install the hot swap disks in the HP Storage System/6 cabinet(s).
  • Page 27: Connecting The Lan Adapters

    Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays System A System B SCSI-B SCSI-A SCSI-B SCSI-A SYSTEM SYSTEM External External CD-ROM CD-ROM DISK DISK SS/6 SS/6 NetRAID NetRAID HP NetServer LH Pro Cluster with Two HP Storage System/6 Units NOTE NetRAID channels must not cross.
  • Page 28 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays The front panel of the storage system includes two-digit, seven-segment LEDs. Because the LEDs are powered by the internal power supply, if the power supply is not functioning you will not see a display. When operations are normal, the display shows "HP"...
  • Page 29 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays To set up your RAID arrays: Review the examples and procedures included in Appendix C before using HP NetRAID Assistant. Follow the procedures outlined in Appendix C for the RAID level appropriate to your installation. Refer to the HP NetRAID User Guide in HP Information Assistant for detailed information about HP NetRAID configuration.
  • Page 30 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays Disk Administrator lists disks in order, beginning with local (non-shared) disks first. If you have three local disks, Disk Administrator will designate them Disk 0, Disk 1, and Disk 2. The shared arrays (logical disks) will be identified as Disk 3, Disk 4, and so on.
  • Page 31 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays In the Assign Drive Letter dialog box, select a drive letter. To avoid confusion later on choose sequential drive letters. From the NT Disk Administrator’s Tools menu, choose Format and, in the space provided, provide a Volume Label for the drive.
  • Page 32 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays Confirming the Arrays on System B To confirm the cluster’s disk configuration, you need to check System B to be sure it recognizes all the drives you created to System A. Boot System B.
  • Page 33 Part 5: Installing HP NetRAID Software and Configuring the Disk Arrays Disk Administrator, Mismatched Drive Letters Click on a disk box to select one of the disks that includes an array to be shared by the cluster. Disk Administrator highlights the selected disk. Select Tools from the pull-down menu, and choose Assign Drive Letter.
  • Page 34: Part 6: Installing And Testing Microsoft Cluster Server Software

    Part 6: Installing and Testing Microsoft Cluster Server Software During installation at System B, you will create a Microsoft Cluster Server. Initially, it is a cluster with only one server, System B. Later, you will join System A to the cluster and thus create a standard two-server cluster. If you ®...
  • Page 35 Part 6: Installing and Testing Microsoft Cluster Server Software Microsoft Cluster Administrator, Assigning a Cluster Name Enter a name for the cluster. Make note of the name you enter here. You will need to provide the identical name during Microsoft Cluster Server software setup at System A.
  • Page 36 Part 6: Installing and Testing Microsoft Cluster Server Software 10. Configure your network resources (LAN adapters). Setup presents a dialog box for each LAN adapter installed in your HP NetServer. The intra-cluster LAN is shown first with the Adapter Name and IP address already filled in (setup supplies the IP address that you specified during NT installation).
  • Page 37 Part 6: Installing and Testing Microsoft Cluster Server Software NOTE If you previously defined Systems A and B as residing on different subnets, the client LAN will be unable to assume responsibility for intra-cluster (heartbeat) communication. 13. Setup prompts you for the Cluster IP address. Input the proper IP address and subnet mask for the CLUSTER.
  • Page 38: Testing The Cluster Installation

    Part 6: Installing and Testing Microsoft Cluster Server Software Testing the Cluster Installation The installation of an HP NetServer cluster is checked by running two tests. The Microsoft Cluster Administrator Sanity test is run, then the HP Cluster Installation Test is run. The Microsoft Cluster Administrator Sanity test is run on a node of the cluster and uses the cluster administrator to perform some basic cluster tests.
  • Page 39 Part 6: Installing and Testing Microsoft Cluster Server Software On each cluster node enable the local disk for sharing. In Windows NT Explorer, right click the local drive, then select Properties | Sharing | Share As | OK. Setting up Two File Shares (use the example below). NOTE When setting up file shares, names must be assigned to resources.
  • Page 40 Part 6: Installing and Testing Microsoft Cluster Server Software On the TCP/IP Address Parameters dialog enter the following, then click Next. : Address. Use the IP address you have allocated for this file share. Subnet Mask. Type in the associated subnet mask for this IP address, then click Finish. Setting Up a Network Name Resource Right click the Disk Group and select New | Resource.
  • Page 41 Part 6: Installing and Testing Microsoft Cluster Server Software On the Disk Parameters dialog complete the following, then click Finish: Name. Type the desired name (e.g., "Disk_U"). Path. Type "C:\" Comment. Nothing needs to be entered here. User Limit. Check Maximum Allowed. Bring Resources Online The file share for this disk group is now complete.
  • Page 42: Appendix A Obtaining Hp Netraid Utilities

    APPENDIX A Obtaining HP NetRAID Utilities To get updated versions of the HP NetRAID utilities that contain firmware, driver and the HP NetRAID Assistant program, you must download, extract, and then copy of nr_clust.exe, a special version of the HP NetRAID utilities for cluster installations.
  • Page 43: Appendix B Updating Hp Netraid Firmware

    APPENDIX B Updating HP NetRAID Firmware After you created your NetRAID utilities diskettes (see Appendix A), use the flash utility diskette labeled NetRAID Firmware & Driver to upgrade the adapter firmware on both systems. To flash the NetRAID adapter firmware: Shut down the system and boot to DOS, Insert the flash utility diskette, NR Firmware &...
  • Page 44: Appendix C Raid Array Configuration

    APPENDIX C RAID Array Configuration The following two examples illustrate the RAID array configuration process for HP NetServer Clusters: Setting up RAID 1 arrays on an HP NetServer cluster Setting up RAID 5 arrays on an HP NetServer cluster After you have finished defining and configuring the cluster’s arrays using HP NetRAID Assistant, you will need to return to Part 5 and finish array configuration using the Windows NT Disk Administrator utility.
  • Page 45 Appendix C RAID Array Configuration From the Windows NT System A Start menu, click Programs | NetRAID | NetRAID Assistant. The HP NetRAID Assistant program loads and displays its main window. HP NetRAID Assistant Screen As you can see on the NetRAID Assistant screen, HP NetRAID Assistant lists the Physical Devices (actual physical drives) and Logical Devices (RAID arrays).
  • Page 46 Appendix C RAID Array Configuration Refer to the HP NetRAID User Guide in Information Assistant for more information about HP NetRAID Assistant. Setting Up the Arrays To set up an array you need to define an array, set its parameters, and then initialize the array. Define an Array RAID arrays are defined using the Configuration Wizard.
  • Page 47: Setting Up Raid 5 Arrays On An Hp Netserver Cluster

    Appendix C RAID Array Configuration Click Next. The Configuration Wizard displays its Logical Drive Definition window. The Logical Drive Definition window shows the array’s RAID level (RAID 1) and its usable size. Notice that the size of the array is one half of the sum of the capacity of the two drives composing the array, since all data is duplicated.
  • Page 48 Appendix C RAID Array Configuration Block 2.1 Parity 2 Block 2.2 Parity 3 Block 3.1 Block 3.2 The preceding table shows how data is distributed for RAID 5. As you can see, each stripe has one block assigned to track parity data. Parity data can be used to reconstruct the data on that stripe if one of the disks should fail. RAID 5 distributes parity information equally among all disk drives to equalize data I/O and achieve better overall performance.
  • Page 49 Appendix C RAID Array Configuration In the Array Definition window define an array by selecting the three physical drives in the Physical Devices pane that will compose the array. As you click your selections, they are highlighted in the Physical Devices pane. Click Add to Array, then Accept Array.

Table of Contents