Configuring Module and Facility Messages Logging
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
340
Command or Action
switch# configure terminal
switch(config)# logging module
[severity-level]
switch(config)# logging level
facility severity-level
switch(config)# no logging
module [severity-level]
switch(config)# no logging level
[facility severity-level]
Configuring System Message Logging
Purpose
Enters configuration mode.
Enables module log messages that have the specified severity
level or higher. Severity levels range from 0 to 7:
• 0 – emergency
• 1 – alert
• 2 – critical
• 3 – error
• 4 – warning
• 5 – notification
• 6 – informational
• 7 – debugging
If the severity level is not specified, the default of 5 is used.
Enables logging messages from the specified facility that have
the specified severity level or higher. Severity levels from 0
to 7:
• 0 – emergency
• 1 – alert
• 2 – critical
• 3 – error
• 4 – warning
• 5 – notification
• 6 – informational
• 7 – debugging
To apply the same severity level to all facilities, use the all
facility. For defaults, see the show logging level command.
(Optional)
Disables module log messages.
(Optional)
Resets the logging severity level for the specified facility to
its default level. If you do not specify a facility and severity
level, the switch resets all facilities to their default levels.