Removing and Replacing a Lithium Battery in the SSM
Removing and Replacing a Lithium Battery in the SSM
To remove and replace the battery in the SSM, perform the following steps:
Step 1
Remove the two screws at the left rear end of the chassis, and remove the slot cover as described in
"Installing and Replacing the Intelligent SSM" section on page
Slide the metal clip back and pull the battery out.
Step 2
Place the used battery aside.
Step 3
Step 4
Replace the battery with a compactible Lithium CR-2032 battery (which is available at your local electronics
or drug store), by sliding the metal clip back and sliding the battery into place.
Replace the chassis cover as described in the
Step 5
page
Removing and Replacing the Power Supply
For information on power supply considerations including environmental operating ranges and power
requirements, see table 7 at the following url:
http://www.cisco.com/en/US/prod/collateral/vpndevc/ps6032/ps6094/ps6120/product_data_sheet0900a
ecd802930c5.html
For information on AC-input power cord options, see
section on page 2-4
This section describes how to remove and replace the power supply, and includes the following topics:
•
•
Removing the AC Power Supply
To remove the AC power supply, perform the following steps:
Power off the adaptive security appliance.
Step 1
Remove the power cord and all other cables from the chassis.
Step 2
Remove the chassis from the rack if it is rack-mounted.
Step 3
Remove the chassis cover. See the
Step 4
for more information.
Place the chassis in an ESD-controlled environment. See the
Step 5
on page 4-3
Cisco ASA 5500 Series Hardware Installation Guide
4-4
4-20.
Removing the AC Power Supply, page 4-4
Replacing the AC Power Supply, page 4-6
for more information.
"Installing and Replacing the Intelligent SSM" section on
Table
2-1in the
"Installing and Replacing the Intelligent SSM" section on page 4-20
"Working in an ESD Environment" section
Chapter 4
Maintenance and Upgrade Procedures
4-20.
"Power Supply Considerations"
78-17989-01