6
146
Interdigit Short Timer
CPC Delay
CPC Duration
Cisco SRP500 Series Services Ready Platforms Administration Guide (SRP520 Models)
Short timeout between entering digits when dialing. The
Interdigit_Short_Timer is used after any one digit, if at
least one matching sequence is complete as dialed, but
more dialed digits would match other as yet incomplete
sequences. Range: 0–64 seconds.
The default is 3.
Delay in seconds after caller hangs up when the SRP
starts removing the tip-and-ring voltage to the attached
equipment of the called party. The range is : 0–255
seconds. This feature is generally used for answer
supervision on the caller side to signal to the attached
equipment when the call has been connected (remote
end has answered) or disconnected (remote end has
hung up). This feature should be disabled for the called
party (in other words, by using the same polarity for
connected and idle state) and the CPC feature should
be used instead.
Without CPC enabled, reorder tone will is played after a
configurable delay. If CPC is enabled, dial tone will be
played when tip-to-ring voltage is restored. Resolution is
1 second.
The default range is 2.
Duration in seconds for which the tip-to-ring voltage is
removed after the caller hangs up. After that, tip-to-ring
voltage is restored and dial tone applies if the attached
equipment is still off-hook. CPC is disabled if this value
is set to 0. Range: 0 to 1.000 second. Resolution is 0.001
second.
The default is 0 (CPC disabled).