Specifications
INSTALLATION DRA WING
Ceramic Heat Exchanger
Separation Circle
Filter Bracket
Outer Pipe
Back Installation Panel
Phillips Screws
Main Machine
Silica Gel Sealing Circle
Rainproof Cover
Temperature Sensor
12V EC Fan
Movable Bracket
Prefilter
Heat Exchanger Bracket
Heat Exchanger Bracket
F7 Filter
7

Overview

OPERATION MODES
Ventilation Mode -
The ventilator runs in exhaust or supply mode at a set speed.
When synchronous operation of two connected ventilators occurs,
one runs in the supply mode and the other in exhaust mode.
Regeneration Mode -
The ventilator runs in two cycles of 75 seconds each, to
provide heat and moisture regeneration.
The warm polluted air is extracted from the room and goes through
Interval 1 -
the ceramic regenerator, which gradually absorbs heat and moisture.
After 75 seconds the ventilator switches to air supply mode.
Interval 2 -
The fresh and cold outdoor air goes through the heat regenerator and
absorbs the accumulated moisture and heat after 75 seconds, and when the
energy regenerator gets cold, the ventilator switches to the exhaust mode.
Exhaust Mode
INSTALLATION AND SETUP
Read The User' s Manual Before Installing The Ventilator
To prevent room dust deposition and accumulation, the ventilator must
CAUTION!
not be installed in places where the air duct may be blocked by any
blinds, curtains, drapes, etc. Window curtains might obstruct normal
airflow in the room, making ventilator operation inefficient.
Exhaust
Mode
75 S
Supply
Mode
Supply Mode
8