Maintenance

MAINTENANCE
Loosen the screws on the top of the main unit.
After unplugging the connecting wires of the
main unit and the inner duct, remove the main
unit and the inner duct from the wall separately.
Pull the cord at both sides of the ceramic
energy regenerator, and F7 medium filter
and remove both the F7 filter and ceramic
energy regenerator from the inner duct.
The ceramic energy regenerator should be
cleaned at least 4 times a year.
The F7 filter should be replaced regularly.
It's recommended to change it after each
time the filter alert displays.
(The ceramic energy regenerator is fragile,
it should be carefully removed to avoid damage.)
The F7 filter is not washable and
should be vacuumed or replaced
when dirty. Please contact your
distributor/vendor to purchase
replacement filters.
Ceramic energy regenerator
(recommended to be
cleaned 4 times a year)
Even regular technical maintenance may not completely prevent dirt accumulation
on the regenerator assemblies.
Treat the exchanger with regular cleaning to ensure high heat exchange efficiency.
Clean the exchanger using a vacuum cleaner at least once a year.
Clean the prefilter at least 4 times a year. The user can wash or vacuum the prefilter.
Note that after washing the prefilter, it should be dried and reinstalled in the air duct.
The lifetime of the prefilter is about 3 years. Purchase replacement filters from vendor.
2
1
Prefilter
Ceramic energy
regenerator cleaning:
This part can be rinsed
directly with water.
Once rinsing is done,
place it in a sunlit
location and wait until
it fully dries.
21
Maintenance
Fan Maintenance (Once Per Year)
Remove the secured bracket from within the inner duct and take out the fan.
Clean the impeller blades. Use a soft brush, doth, or a vacuum cleaner to clean the impeller. Do not use
water, abrasive detergents, solvents, or sharp objects. The impeller blades must be cleaned once a year.
STORAGE AND TRANSPORTATION GUIDELINES
Store the ventilator inside the manufacturer's original packing box in a cool, dry place.
The storage environment must be free of any aggressive vapors and chemical mixtures that
may cause corrosion, insulation, and sealing deformation. Use lifting equipment for handling
and storage operations to prevent ventilator from damage as a consequence of failing or
excessive vibration. Fulfill the handling requirements relevant to the applicable freight type.
Transportation via any type of vehicle is allowed, provided that the ventilator is protected against
mechanical and weather damage.
Take care to avoid any mechanical shocks and sharp ends during handling operations.