Page 1
Installation Guide and Operating Manual Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 Fire Sentry Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors (Models SS3-A, SS3-AN, SS3-AB, and SS3-ABN) Stand-Alone Mode or FS2000 System Mode ____________________________________________________________________________________________________________________ Fire Sentry Corporation Document No.
Page 2
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12...
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 SECTION 1 FAMILIARIZATION Introduction The Model SS3 Optical Fire/Flame Detectors operate the whether they are connected to the SAME FS2000 Fire Early Warning System (with FS2000 Controller and FireBus) or whether they operate in the Stand-Alone configuration.
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 SECTION 2 INSTALLATION Installation Procedure This section describes the installation of the Model SS3 Detector for the Stand-Alone mode. It is recommended that junction boxes be used to wire the Model SS3 Detectors.. 2.1.1 Installation Precautions The following precautions should be observed during installation of Model SS3...
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 2.3.1 Wiring as Standalone Connect the 24 volt DC Power Supply wires into the connector and firmly tighten down the slotted screws with a small screwdriver. DO NOT CONNECT ANY WIRES TO J1 - Pin 2 or J1 - Pin 3. Do NOT over tighten or the screws may strip or break.
Page 7
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 Figure Model SS3 Detector Connection Diagrams Figure 2 Model SS3 Detectors Wiring...
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 SECTION 3 MAINTENANCE AND TROUBLESHOOTING Personnel The following will aid in troubleshooting the Model SS3 Detectors. Tests must be performed by qualified authorized personnel observing standard safety practices. Although the Model SS3 Detector operates on safe 24 volts DC, the FM/UL Approved Fire Alarm Panel's power supply may operate on a dangerous 120 or 240 volts AC.
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 SECTION 4 DETECTOR DATA Table 1: Model SS3 Detector Connectors - Pinouts DETECTOR INPUT POWER FIRE RELAY 1 DC Return or Ground (-) 5 Fire Relay EOL Resistor (10K ohms) 2 FireBus Communication (-) 6 Fire Relay Normally Closed 3 FireBus Communication (+)
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 Mechanical Layouts P.N. 188424 for SS3-A and SS3-AN P.N. 188424(B) for SS3-AB and SS3-ABN (Included with Detector) (Included with Detector) Figure 3 Model SS3 Detector Mounting Brackets...
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 Figure 4 Model SS3-A and SS3-AN Detectors Figure 5 Model SS3-AB and SS3-ABN Detectors...
Model SS3 Multi-Spectrum Digital Electro-Optical Fire Detectors Installation Guide and Operating Manual MAN0932_V1_1508002_Rev B_08-12 INDEX False Alarms, 1 Layout Planning, 2 Cleaning Products, 5 See Detector, 1 FireBus, 1 Stand-Alone, 1 FireBus Wiring, 2 FireLogic, 1 Detector Maintenance, 5 Flame Detector Cleaning, 5 Mounting Brackets, 7 Test Source, 1...
Page 13
Asia Pacific Data may change, as well as legislation, and you are strongly advised to Honeywell Analytics Asia Pacific obtain copies of the most recently issued regulations, standards, and #508, Kolon Science Valley (I) guidelines.