SiXCO
Wireless Carbon Monoxide (CO) Detector/ Wireless Carbon Monoxide (CO) Detector
Installation Instructions
This device is intended for use with Honeywell control
panels that support SiX series devices. Before installing
detectors, please thoroughly read these installation
instructions.
Features
• 10-year life
• CO Detector End-of-Life reporting (detector needs
replacing)
• Carbon Monoxide detector maintenance reporting
• Low Battery Detection
• Multi-color status LED
POWER UP
Remove battery pull tab. Be sure
batteries are seated properly to
avoid a low battery condition
after 15 seconds.
Upon power up, Green LED
Blinks every 2 secs / Sounder is
Silent.
ENROLLMENT
This device can be enrolled and programmed either
before or after installation.
Set the Lyric Controller in Programming Mode and go to
1.
Zone Programming. Select Add New and then Serial
Number.
Remove the battery tabs to activate the device and begin
2.
the enrollment process.
The Green LED flashes rapidly during enrollment (up to
3.
about 20 seconds).
*NOTE: Enrollment time varies depending on the signal
strength between the device and the controller.
• The detector sends its unique MAC ID (Serial Number)
and Services information to the controller.
• The controller registers the device and displays the
transmitter data on screen.
Enrollment is confirmed when the Green LED is ON for 3
4.
seconds and the detector chirps.
Press SAVE.
5.
Instructions d'installation
This device is intended for use with Honeywell
control panels that support SiX series devices.
Before installing detectors, please thoroughly read
these installation instructions.
Features
• 10-year life
• CO Detector End-of-Life reporting
• Carbon Monoxide detector maintenance reporting
• Low Battery Detection
• Multi-color status LED
ENRÔLEMENT
Le dispositif peut être enrôlé et programmé avant
ou après l'installation.
1. Réglez le contrôleur Lyric en mode de
programmation et accédez à la programmation
des zones. Sélectionnez Add New (ajouter
nouveau) et ensuite Serial Number (numéro de
série).
2. Retirez la languette qui recouvre la pile pour
activer le dispositif et commencer la procédure
d'enrôlement.
3. La DEL verte clignote durant l'enrôlement
(pendant jusqu'à environ 20 secondes*).
NOTE:
La durée de l'enrôlement varie selon la
puissance du signal entre le dispositif et
le contrôleur.
• Le dispositif transmet au contrôleur son ID
MAC (numéro de série) et l'information pour les
services.
• Le contrôleur enregistre le dispositif et affiche
les données du transmetteur sur l'écran.
POWER UP
Remove battery pull tab. Be
sure batteries are seated
properly to avoid a low
battery condition after 15
seconds.
Upon power up, Green LED
Blinks every 2 secs /
Sounder is Silent.

Advertisement

loading

Summary of Contents for Honeywell SiX Series

  • Page 1 Wireless Carbon Monoxide (CO) Detector/ Wireless Carbon Monoxide (CO) Detector Installation Instructions Instructions d’installation This device is intended for use with Honeywell control This device is intended for use with Honeywell panels that support SiX series devices. Before installing control panels that support SiX series devices.
  • Page 2 If the detector is not successfully enrolled during the 4. L'enrôlement est confirmé lorsque la DEL verte est enrollment period, the LED turns off and the device allumée durant 3 secondes et que le dispositif émet powers down. Pressing and holding the test button, while un pépiement .
  • Page 3: Montage

    MOUNTING MONTAGE After enrolling and before mounting permanently, After enrolling and before mounting permanently, conduct Go/No Go test (see controller’s instructions) to conduct Go/No Go test (see controller’s instructions) to verify adequate signal strength. Adjust the device verify adequate signal strength. Adjust the device location as necessary.
  • Page 4 TESTING TESTING Test communications between the detector and the Test communications between the detector and the control panel. The detector has one test button (for control panel. The detector mode has one test button testing CO). (for testing CO) The detector may also be functionally tested using The detector may also be functionally tested using canned CO.
  • Page 5 HUSH FEATURE / ALARM SILENCE HUSH FEATURE / ALARM SILENCE If required, the audible alarm for CO conditions can be If required, the audible alarm for CO conditions can be silenced for 5 minutes by pushing the “Test/Hush” silenced for 5 minutes by pushing the “Test/Hush” button.
  • Page 6 REPLACING THE BATTERIES REPLACING THE BATTERIES Remove old batteries. Wait 10 seconds and then Remove old batteries. Wait 10 seconds and then replace replace with two new batteries. To avoid a low battery with two new batteries. To avoid a low battery indication indication when installing new batteries, both batteries when installing new batteries, both batteries must be must be installed within 15 seconds of installing the...
  • Page 7: Maintenance

    MAINTENANCE MAINTENANCE Do not paint, and do not use cleaning agents, bleach Do not paint, and do not use cleaning agents, bleach or polish the detector. or polish the detector. NOTE: Before performing any maintenance on the NOTE: Before performing any maintenance on the detector, notify the proper authorities and detector, notify the proper authorities and Central Station that maintenance is being...
  • Page 8: Symptoms Of Carbon Monoxide Poisoning

    LED INDICATORS / LED INDICATORS The SiXCO has a multi-color top LED: Green/Green ...... Supervisory indication; blinks during power on, reset, and during normal operation Supervisory indication; blinks during power on, reset, and during normal operation Amber / Amber ....Signal maintenance and trouble events / Signal maintenance and trouble events Red .........
  • Page 9 LIMITED LIFE OF CO SENSOR LIMITED LIFE OF CO SENSOR This detector is manufactured with a long-life This detector is manufactured with a long-life electrochemical carbon monoxide sensor. Over time the electrochemical carbon monoxide sensor. Over time the sensor will lose sensitivity and will need to be replaced. sensor will lose sensitivity and will need to be replaced.
  • Page 10 CO ALARM ACTIVATION CO ALARM ACTIVATION Per UL standard 2075, the SiXCO detector has been Per UL standard 2075, the SiXCO detector has been tested to the sensitivity limits defined in UL standard tested to the sensitivity limits defined in UL standard 2034.
  • Page 11 RF EXPOSURE Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures.
  • Page 12 For patent information, see www.honeywell.com/patents Pour des informations sur les brevets, voir www.honeywell.com/patents  2017 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Ê800-23974lŠ Inc. All other trademarks are the properties of their respective owners. All rights reserved.