Enroll and Program the SiXFOB
1. Set the Lyric Controller in Programming mode. Go to the
Keys enrollment screen, select Add New, select "Key Fob"*
Key Type and select Serial Number. (*Refer to For SIA
Installations section below for SIA selections.)
2. Press and hold the top two buttons for about two seconds to
activate the enrollment process.
The LEDs alternately flash green during enrollment (up to
3.
about 20 seconds).
NOTE: Enrollment time varies depending on the signal strength
between the device and the controller.
• The device sends its unique MAC ID (Serial Number) and
Services information to the controller.
• The controller registers the device and displays the
transmitter data on screen.
4. The LEDs light solid green for 3 seconds and the SiXFOB
emits a chirp to confirm enrollment.
5. Press the top two buttons again to complete enrollment.
NOTE: If enrollment is not confirmed, press and hold the top two
buttons for two seconds again to restart the enrollment process.
6. Use Zone Program menu to change default key functions as
desired.
7. Assign a User Number to the key fob and press SAVE.
Follow instructions in the Controller's programming guide to
program the SiXFOB services.
The device can also be manually enrolled. See the Controller's
Programming Guide for details.
After enrolling, update the SiXCT firmware (via the
Controller) to ensure the latest version is used. See the
Controller's instructions.
*For SIA Installations
There are two methods to enroll the device when two-button press is required for Panic functions.
Method A (uses 8 zones in the system): Follow the directions above, except select Key Type "8 Button" and program
Button Key 8 for the desired panic function. Continue the directions above to complete enrollment.
Method B (uses 6 zones in the system): Follow the direction above except select Key Type "6 Button". Continue the
directions above to assign the desired panic function to Button 6. Take note of the Zone number assigned to Button 6.
After assigning the User Number and selecting SAVE, enter Zone Programming mode. Scroll to the Button 6 Zone
number and reassign the Loop for Button 6 to Loop 5. Select SAVE.
SiXFOB
Button Keys 1-4
(Corresponding Loop numbers are
seen when programming the key
fob through the Zone Programming
menu.)
*SIA NOTE: SIA requires 2-button press for
panic functions. Select "8 Button" (or "6
Button") Key Type and follow the directions
in the For SIA Installations section below.
Programming Mode > Keys > Add New >
Select Key Type [
1
Serial Number
Zone Description 1
Device Type
Alarm Report
Panic
6
Assign the desired Zone Type for each button key.
7
Assign a User Number for the Key Fob and press SAVE.
NOTE: Once enrolled in a system, the SiXFOB
cannot be used with another controller until it is
removed from the current controller. When
removed from a system, the key fob will revert to
factory default settings.
Installation Instructions
1
(Loop 3)
3
(Loop 4)
] > Serial Number
Key Fob*
2
Loop Number
Zone Description 2
Response Type
Chime
Supervision
Home
3
0
10
LEDs flash alternately
45
20
Up to about 20 seconds
30
4
LEDs
ON for
3 seconds
2
(Loop 2)
4
8*
(Loop 1)
(Loop 5)
~ 2 seconds
5
Press the