Figure 4
To prevent damage to the backplane, you must install the RSP8 in one of the two RSP slots on the router.
Caution
The slots are keyed for correct installation. Forcing the RSP8 into a different slot can damage the
backplane and the RSP8.
While keeping the RSP8 parallel to the backplane, carefully slide the carrier into the slot until the RSP8
Step 3
faceplate makes contact with the ejector levers, and then stop. (See
Step 4
Using the thumb and forefinger of each hand to pinch each ejector lever, simultaneously push both
ejector levers inward (toward the handle) until they are parallel to the faceplate. (See
Step 5
Use a screwdriver to tighten the captive installation screws on the ends of the RSP8. (See
Step 6
Use a screwdriver to tighten the two captive installation screws on the RSP8 faceplate to prevent the
RSP8 from becoming partially dislodged from the backplane and to ensure proper EMI shielding. (These
screws must be tightened to meet EMI specifications.)
If you disconnected the console terminal to remove the RSP8, or if you are installing a new RSP8,
Step 7
connect the console terminal to the console port. (See the
page
20.)
Ensure that a console terminal is connected (see the
Step 8
page
20) and that it is turned on.
Turn the system power back on, and proceed to the
Step 9
the installation.
This completes the procedure for replacing the RSP8.
OL-4920-02
Handling the RSP8 During Removal and Installation
Route Switch Processor (RSP8) Installation and Configuration Guide
Figure
3b.)
"Connecting a Console Terminal" section on
"Connecting a Console Terminal" section on
"Restarting the System" section on page 21
Installing the RSP8