Installing the Router
Step 2
Attach the DIN mounting bracket to the router using the four 8-32 screws provided in the kit. Position the
bracket over the four mounting holes and insert the screws through the bracket into the chassis. Then use 14
in. lbs. of torque to screw the bracket onto the router.
Step 3
After the bracket is attached to the router, it can be mounted onto the DIN rail.

Installing the Router Ground Connection

Warning
This equipment is intended to be grounded to comply with emission and immunity requirements. Ensure that
the switch functional ground lug is connected to earth ground during normal use. Statement 1064
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence
of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician
if you are uncertain that suitable grounding is available. Statement 1024
Note
Cable distribution system should be grounded (earthed) in accordance with ANSI/NFPA 70, the National
Electrical Code (NEC), in particular Section 820.93, Grounding of Outer Conductive Shield of a Coaxial Cable.
Cisco Catalyst IR1800 Rugged Series Router Hardware Installation Guide

Installing the Router Ground Connection

37