hit counter script

Siemens SINAMICS Series Operating Instructions Manual page 430

Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Descriptions of functions
10.3 Communication according to PROFIdrive
Encoder n status word (Gn_ZSW, n = 1, 2)
The encoder status word is used to display states, errors and acknowledgements.
See function diagram [4730]
Table 10- 18 Description of the individual signals in Gn_ZSW
Bit
Name
0
Reference
Status:
mark search
Function 1 - 4
1
active
2
3
4
Status:
Value 1 - 4
5
available
6
7
8
Reserved
9
Reserved
10
Reserved
11
Encoder fault acknowledge
active
12
Reserved
428
Signal status, description
Valid for "Reference mark search" and "Flying measurement"
Bit
Meaning
0
Function 1
1
Function 2
2
Function 3
3
Function 4
Note:
Bit x = 1 function active
Bit x = 0 function inactive
Applies to reference mark search
Bit
Meaning
4
Value 1
5
Value 2
6
Value 3
7
Value 4
Note:
Bit x = 1 value available
Bit x = 0 value not available
Only one single value can be retrieved.
Reason: There is only one common status word Gn_XIST2 to read the values.
1
Reserved
0
Reserved
1
Reserved
0
Reserved
-
1
Encoder fault acknowledge active
Note:
See at STW.15 (acknowledge encoder error)
0
No acknowledgement active
-
Reference mark 1
Reference mark 2
Reference mark 3
Reference mark 4
Reference mark 1
Probe 1 rising edge
Reserved
Reserved
Reserved
SINAMICS DCM DC Converter