hit counter script

Loop Power; Typical Connection Drawing; A.6 Loop Power - Siemens SITRANS LR560 Operating Instructions Manual

Radar transmitters ma/hart
Hide thumbs Also See for SITRANS LR560:
Table of Contents

Advertisement

Technical reference

A.6 Loop Power

A.6

Loop Power

A.6.1

Typical connection drawing

Note
Loop voltage is the voltage at the terminals of the power supply (not the voltage at the
terminals of the device).
190
ambient temperature
–40 °C to 80 °C
(–40 °F to 176 °F)
process temperature:
–40 to +100 °C (–40 to +212 °F) or
–40 to +200 °C (–40 to +392 °F) depending on the version
Loop voltage
Power supply
Loop resistance RL
SITRANS LR560
Loop current IL
Operating Instructions, 06/2017, A5E34647946-AD
SITRANS LR560 (mA/HART)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans l series

Table of Contents