Page 2
Introduction Safety notes Description SITRANS L Installing/mounting Radar Transmitters SITRANS LR100 Connecting Access protection Operating Instructions Setup with smartphone/ tablet (Bluetooth) Operating Diagnostics and troubleshooting Service and maintenance Technical data and dimensions 01/2020 A5E49829004...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of Contents Introduction ........................... 1 Function ........................ 1 Target group ......................1 Symbols used ......................1 Safety notes .......................... 3 Authorised personnel .................... 3 Appropriate use ....................3 Warning about incorrect use ................. 3 General safety instructions ..................3 EU conformity .......................
Page 5
Table of Contents Setup with smartphone/tablet (Bluetooth) ................. 21 Connecting ......................21 Operating ..........................23 Diagnostics and troubleshooting ..................27 Maintenance ....................... 27 Rectify faults ....................... 27 Diagnosis, fault messages ................... 28 Status messages according to NE 107 ..............28 Treatment of measurement errors ............... 32 Return procedure ....................
Introduction Function This instruction provides all the information you need for mounting, connection and setup as well as important instructions for maintenance, fault rectification, the exchange of parts and the safety of the user. Please read this information before putting the transmitter into operation and keep this manual accessible in the imme- diate vicinity of the device.
Page 7
Introduction 1.3 Symbols used Sequence of actions Numbers set in front indicate successive steps in a procedure. Battery disposal This symbol indicates special information about the disposal of batteries and accumulators. SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Safety notes Authorised personnel All operations described in this documentation must be carried out only by trained, qualified personnel authorised by the plant operator. During work on and with the device, the required personal protective equipment must always be worn. Appropriate use SITRANS LR100 is a transmitter for continuous level measurement.
Safety notes 2.5 EU conformity The safety instructions in this operating instructions manual, the national installation standards as well as the valid safety regulations and accident prevention rules must be observed by the user. For safety and warranty reasons, any invasive work on the device beyond that de- scribed in the operating instructions manual may be carried out only by personnel authorised by the manufacturer.
To protect plants, systems, machines and networks against cyber threats, it is neces- sary to implement (and continuously maintain) a holistic, state-of-the-art industrial security concept. Siemens products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, sys- tems, machines and networks.
Description Configuration Scope of delivery The scope of delivery encompasses: • SITRANS LR100 radar transmitter Information sheet "Documents and software" with: • • Transmitter serial number • QR code with link for direct scanning • Information sheet "Device Bluetooth and Parameter Access Codes " with: •...
Description 3.2 Principle of operation Constituent parts Radar antenna Process fitting Electronics housing Mounting thread Connection cable Figure 3.1 Components of SITRANS LR100 Nameplate The nameplate contains the most important data for identification and use of the transmitter. Transmitter type Serial number Technical data Field for approvals QR code for device documentation...
Description 3.3 Adjustment Functional principle The transmitter emits a continuous, frequency-modulated radar signal through its antenna. The emitted signal is reflected by the medium and received by the antenna as an echo with modified frequency. The frequency change is proportional to the dis-tance and is converted into the level.
Description 3.5 Accessories Transport inspection The delivery must be checked for completeness and possible transit damage imme- diately at receipt. Ascertained transit damage or concealed defects must be appropri- ately dealt with. Storage Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Installing/mounting General instructions Ambient conditions The transmitter is suitable for standard and extended ambient conditions acc. to DIN/ EN/IEC/ANSI/ISA/UL/CSA 61010-1. It can be used indoors as well as outdoors. Process conditions WARNING For safety reasons, the transmitter must only be operated within the permissible process conditions.
Installing/mounting 4.3 Mounting instructions Figure 4.1 Mounting via a mounting bracket Mounting instructions Installation position When mounting the transmitter, keep a distance of at least 200 mm (7.874 in) from the vessel wall. If the transmitter is installed in the center of dished or round vessel tops, multiple echoes can arise.
Page 18
Installing/mounting 4.3 Mounting instructions Reference point Figure 4.3 Reference point Inflowing medium Do not mount the transmitters in or above the filling stream. Make sure that you de- tect the product surface, not the inflowing product. Figure 4.4 Mounting of the radar transmitter with inflowing medium Mounting nozzle For nozzle mounting, the nozzle should be as short as possible and its end rounded.
Page 19
Installing/mounting 4.3 Mounting instructions Figure 4.6 Nozzle mounting with deviating nozzle dimensions Nozzle diameter d Nozzle length h 40 mm 1½" ≤ 150 mm ≤ 5.9 in 50 mm 2" ≤ 200 mm ≤ 7.9 in 80 mm 3" ≤ 300 mm ≤ 11.8 in 100 mm 4" ≤ 400 mm ≤ 15.8 in 150 mm 6" ≤ 600 mm ≤ 23.6 in Transmitter orientation In liquids, direct the transmitter as perpendicular as possible to the product surface to achieve optimum measurement results.
Installing/mounting 4.4 Measurement setup - Flow Figure 4.8 Agitators Foam generation Through the action of filling, stirring and other processes in the vessel, compact foams which considerably damp the emitted signals may form on the product sur- face. If foams lead to measurement errors, you should use the transmitters with guided radar.
Page 21
Installing/mounting 4.4 Measurement setup - Flow Khafagi-Venturi flume Position transmitter Venturi flume Figure 4.10 Flow measurement with Khafagi-Venturi flume: h = max. filling of the flume max. SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Connecting Preparing the connection Safety instructions Always keep in mind the following safety instructions: • Carry out electrical connection by trained, qualified personnel authorised by the plant operator • If overvoltage surges are expected, overvoltage arresters should be installed WARNING Only connect or disconnect in de-energized state.
Connecting 5.2 Wiring plan Cable screening and grounding If shielded cable is required, we recommend that the cable screening be connected to ground potential on one side of the supply side. In Ex systems, the grounding is carried out according to the installation regulations. Wiring plan Wire assignment, connection cable Figure 5.1...
Access protection Bluetooth radio interface Devices with a Bluetooth radio interface are protected against unwanted access from outside. This means that only authorized persons can receive measured and status values and change device settings via this interface. Bluetooth PIN A Bluetooth PIN is required to establish Bluetooth communication via the adjustment tool (smartphone/tablet/notebook).
Page 25
Access protection 6.2 Protection of the parameterization Device Access PUK The Device Access PUK allows unlocking the device in case the user PIN is no longer known. It can't be changed. The Device Access PUK can also be found on the supplied information sheet "Device Bluetooth and Parameter Access Codes".
Setup with smartphone/tablet (Bluetooth) Connecting Connecting Start the adjustment app. The smartphone/tablet searches automatically for Blue- tooth-capable transmitters in the area. The devices found are listed. Select the requested transmitter in the device list. Authenticate For the first connection, the adjustment tool and the transmitter must authenticate each other.
Operating To configure the device: Download and install the SITRANS mobile IQ app from the App store to your mo- bile device. Launch the app. Devices in range will appear. Click on the device you wish to connect to. On first connection, a PIN code shipped with the device needs to be entered (see Device Bluetooth and Parame- SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Page 29
Operating ter Access Codes sheet). Following successful PIN entry, the device cockpit will be shown. SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Page 30
Operating Use the Setup/Quick Commissioning to configure the transmitter for your appli- cation type. SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Page 31
Operating Many diagnostic tools are supported, including the echo profile viewer: SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Diagnostics and troubleshooting Maintenance Maintenance If the device is used properly, no special maintenance is required in normal opera- tion. Precaution measures against buildup In some applications, buildup on the antenna system can influence the measuring result. Depending on the transmitter and application, take measures to avoid heavy soiling of the antenna system.
Diagnostics and troubleshooting 9.3 Diagnosis, fault messages • Signal processing Fault rectification The first measures are: • Evaluation of fault messages • Checking the output signal • Treatment of measurement errors A smartphone/tablet with the adjustment app or a PC/notebook with the PDM and the suitable EDD offer you further comprehensive diagnostic possibilities.
Page 34
Diagnostics and troubleshooting 9.4 Status messages according to NE 107 Status messages The status messages are divided into the following categories: • Failure • Function check • Out of specification • Maintenance requirement and explained by pictographs: Failure - red Out of specification - yellow Function check - orange Maintenance - blue Figure 9.1...
Page 35
Diagnostics and troubleshooting 9.4 Status messages according to NE 107 Code Cause Rectification DevSpec Text message State in CMD 48 F017 Adjustment not within Change adjustment Byte 5, Bit 1 of specification according to the limit Byte 0 … 5 Adjustment span too values (difference be- small tween min.
Page 36
Diagnostics and troubleshooting 9.4 Status messages according to NE 107 Out of specification Code Cause Rectification DevSpec Text message State in CMD 48 S600 Temperature of the Check ambient temper- Byte 23, Bit 4 of electronics in the non- ature Byte 14 … 24 Impermissible electron- specified range ics temperature Insulate electronics S601...
Diagnostics and troubleshooting 9.5 Treatment of measurement errors Code Cause Rectification DevSpec Text message State in CMD 48 M510 Bit 10 of Byte 14 … 24 No communication with the transmitter Treatment of measurement errors The tables below give typical examples of application-related measurement errors. The images in column "Error description"...
Page 38
Diagnostics and troubleshooting 9.5 Treatment of measurement errors Fault description Cause Rectification Max. adjustment not correct Check measuring point: Anten- na should protrude out of the threaded mounting nozzle, pos- sible false echoes through flange nozzle? Remove contamination on the antenna In case of interferences due to installations in the close range, change polarisation direction...
Page 39
Diagnostics and troubleshooting 9.5 Treatment of measurement errors Fault description Cause Rectification After eliminating the false sig- nals, the auto false echo sup- pression must be deleted. Carry out a new auto false echo sup- pression Measured value jumps sporadi- Varying condensation or conta- Carry out auto false echo sup- cally towards 100 % during emp- mination on the antenna...
Page 40
Diagnostics and troubleshooting 9.5 Treatment of measurement errors Fault description Cause Rectification Transverse reflection from an ex- Direct transmitter to the oppo- traction funnel, amplitude of the site funnel wall, avoid crossing transverse reflection larger than with the filling stream the level echo Measured value fluctuates Various echoes from an uneven Check parameter "Material Type"...
Reason for returning the item(s) • Decontamination declaration • https://www.siemens.com/sc/declarationofdecontamination With this declaration you warrant "that the device/replacement part has been careful- ly cleaned and is free of residues. The device/replacement part does not pose a haz- ard for humans and the environment."...
You can find certificates in the Internet under http://www.siemens.com/processin- strumentation/certificates or on an included DVD. How to proceed if a repair is necessary If it is necessary to repair the transmitter, please contact Siemens. You find the loca- tions on "www.siemens.com/processautomation [https:://www.siemens.com/proces- sautomation]". SITRANS LR100...
Page 43
Diagnostics and troubleshooting 9.8 How to proceed if a repair is necessary SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Devices can be returned to the supplier within the EC, or to a locally approved dis- posal service for eco-friendly recycling. Observe the specific regulations valid in your country. Further information about devices containing batteries can be found at: (https://sup- port.industry.siemens.com/cs/document/109479891/) Note Special disposal required The device includes components that require special disposal. •...
Page 45
Service and maintenance 10.2 Disposal SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Technical data Note for approved transmitters Device specifications: Siemens makes every effort to ensure the accuracy of these specifications, but re- serves the right to change them at any time. Device-specific approvals: The device-specific approvals are always to be found on the type plates on the de- vice.
Page 47
Technical data and dimensions 11.1 Technical data Input variable Measured variable The measured variable is the distance between the antenna edge of the transmitter and the product surface. The antenna edge is also the reference point for the measurement. Max. measuring 8 m (26.25 ft) range Depending on application and medium...
Page 48
Technical data and dimensions 11.1 Technical data Reflector Flat plate reflector False reflections Biggest false signal, 20 dB smaller than the useful signal Variables influencing measurement accuracy Temperature drift - < 0.03 %/10 K relating to the 16 mA span or ≤ 0.3 % Current output Deviation in the cur- < 15 µA rent output due to dig- ital/analogue conver-...
Page 49
Technical data and dimensions 11.1 Technical data Process conditions For the process conditions, please also note the specifications on the nameplate. The lowest value (amount) always applies. Process temperature -40 … +60 °C (-40 … +140 °F) Process pressure -1 … 3 bar (-100 … 200 kPa/-14.5 … 43.51 psig) Bluetooth interface Bluetooth standard Bluetooth 5.0 (downward compatible to Bluetooth 4.0 LE) Frequency 2.402 ...
Technical data and dimensions 11.2 Dimensions 11.2 Dimensions Figure 11.1 Dimensions SITRANS LR100 11.3 License information for Open Source Software Hashfunction acc. to mbed TLS: Copyright (C) 2006-2015, ARM Limited, All Rights Re- served SPDX-License-Identifier: Apache-2.0 Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except in compliance with the License.
Page 51
Technical data and dimensions 11.4 Trademark SITRANS LR100 Operating Instructions, 01/2020, A5E49829004...
Page 52
Further Information Process Automation https://www.siemens.com/processautomation Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...