hit counter script

Expansion Module Diagnostics - Cisco Nexus 5600 Series Configuration Manual

Nx-os system management
Hide thumbs Also See for Nexus 5600 Series:
Table of Contents

Advertisement

Configuring Online Diagnostics
Diagnostic
Fabric engine
Fabric port
Forwarding engine
Forwarding engine port
Front port
Note
When the switch exceeds the intake temperature threshold of 40 degrees Celsius and does not decrease
to within the threshold limits in 120 seconds, the switch powers off and the power supplies must be
re-seated to recover the switch.

Expansion Module Diagnostics

During the switch bootup or reset, the bootup diagnostics include tests for the in-service expansion modules
in the switch.
When you insert an expansion module into a running switch, a set of diagnostics tests are run. The following
table describes the bootup diagnostics for an expansion module. These tests are common with the bootup
diagnostics. If the bootup diagnostics fail, the expansion module is not placed into service.
Table 9: Expansion Module Bootup and Health Monitoring Diagnostics
Diagnostic
SPROM
Fabric engine
Fabric port
Forwarding engine
Forwarding engine port
Front port
OL-31641-01
Cisco Nexus 5600 Series NX-OS System Management Configuration Guide, Release 7.x
Expansion Module Diagnostics
Description
Tests the switch fabric ASICs.
Tests the ports on the switch fabric ASIC.
Tests the forwarding engine ASICs.
Tests the ports on the forwarding engine ASICs.
Tests the components (such as PHY and MAC) on
the front ports.
Description
Verifies the integrity of backplane and supervisor
SPROMs.
Tests the switch fabric ASICs.
Tests the ports on the switch fabric ASIC.
Tests the forwarding engine ASICs.
Tests the ports on the forwarding engine ASICs.
Tests the components (such as PHY and MAC) on
the front ports.
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents