• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • List of Figures..............................v Conventions Used in This Manual........................vi SECTION 1: General Description ........................1-1 About the VISTA-128BP/VISTA-250BP........................1-1 Features ..................................1-2 SECTION 2: Partitioning and Panel Linking....................2-1 Theory of Partitioning ..............................2-1 Setting-Up a Partitioned System ..........................
Page 4
Table of Contents Programming for TeleSmart ............................. 4-10 SECTION 5: Data Field Descriptions ......................5-1 About Data Field Programming........................... 5-1 Programming Data Fields ............................5-1 SECTION 6: Scheduling Options ........................6-1 Time Window Definitions ............................6-2 Open/Close Schedules Definitions ..........................6-3 Scheduling Menu Mode ..............................
Conventions Used in This Manual • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Before you begin using this manual, it is important that you understand the meaning of the following symbols (icons).
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • About the VISTA-128BP/VISTA-250BP All references to the VISTA-128BP also pertain to the VISTA-128SIA. The differences between the two panels are outlined in the supplement accompanying the VISTA-128SIA. The supplement must be referred to when programming the VISTA-128SIA.
Supports up to 241 additional expansion zones (119 for the VISTA-128BP) using a built-in polling (multiplex) loop. • Supports up to 250 wireless zones (128 for the VISTA-128BP) (fewer if using hardwire and/or polling loop zones). The 5881ENHC RF Receiver and the 5869 Holdup Switch Transmitter are listed for UL Commercial Burglary applications.
Page 9
Provides an End User Output Programming Mode, allowing the user to control outputs. Access Control • Supports up to 15 VistaKey modules (15 access points) (VISTA-128BP supports 8 modules), which are used for access control. It is a single-door access control module. •...
Page 10
VISTA-128BP/VISTA-250BP Installation and Setup Guide Downloading • Supports upload and download capability. • Can perform unattended downloading (no one at the downloading computer). • Provides an Installer Unattended Program Mode. This allows the installer to program the download phone number, subscriber number, and primary central station receiver phone number without entering the normal program mode.
S E C T I O N Partitioning and Panel Linking • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Theory of Partitioning This system provides the ability to arm and disarm up Zones...
Page 12
VISTA-128BP/VISTA-250BP Installation and Setup Guide 1*18 Affects Lobby (must be programmed by Example partition) Here is an example of how the lobby would react in a typical setup. Setting this field to 1 for a specific partition causes that partition to affect the operation of the common...
Section 3 - Installing the Control How User Access Codes Affect the Common Lobby Arming/Disarming Remotely If a user arms or disarms remotely (through Compass Codes with Global Arming downloading software), the lobby does not If a code is given "global arming" when it is defined automatically follow another partition that is (see SECTION 9: User Access Codes), the keypad programmed to arm or disarm the lobby.
Trouble sounds (rapid beeping) Therefore, panics must be programmed for Partition 1. Panel Linking Up to eight VISTA-128BP/VISTA-250BP control panels Panel Link Module Supervision may be networked, enabling a user to control the The Panel Link Module can be supervised for its features of all control panels from a single location.
Page 15
Section 3 - Installing the Control Single-Partition Single-Panel Mode To access the Single-Partition, Single Panel mode, perform the following steps: Step Action Enter User Code (for users 001-050) + [#] + [86]. Enter the panel ID number (01-08) of the panel you want to link to. Enter the partition number of the panel.
Page 16
When performing either a STAY or INSTANT arm command, the system always arms in mode 1 (see the VISTA-128BP/VISTA-250BP User Guide for a detailed explanation of the STAY and INSTANT arming modes).
NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. Mounting the Control Cabinet...
VISTA-128BP/VISTA-250BP Installation and Setup Guide (Shows typical local Grade A listing installation) RUN BELL WIRES IN CONDUIT PLUG THIS KNOCKOUT TO PLUG AN UNUSED KNOCKOUT OPENING, REMOVE KNOCKOUT AND INSTALL A PAIR OF CLIP-ON DOOR DISC PLUGS AND A CARRIAGE BOLT AS SHOWN.
Section 3 - Installing the Control Installing the Keypads • Addressing the Keypads Up to 31 addressable keypads (addresses 00-30) may be used (you may need to use an auxiliary The keypads will not operate until they are power supply if the 750mA aux. output is physically addressed and enabled in the exceeded).
VISTA-128BP/VISTA-250BP Installation and Setup Guide Installing External Sounders The VISTA-128BP/VISTA-250BP provides a bell circuit Alarm Output Supervision output for operating fire and burglary alarm When supervision is enabled, the VISTA- notification appliances. The alarm output is rated as 128BP/VISTA-250BP monitors the alarm output follows: 10VDC –...
Section 3 - Installing the Control POLARIZING DIODES (MUST MOUNT AT INDICATING DEVICE) PANEL BELL HORN OTHER BELL BELL DEVICES PANEL BELL NONPOLARIZED BURGLARY POLARIZED FIRE INDICATING DEVICES INDICATING DEVICE non_polar_devices Figure 3-7: Wiring Nonpolarized Burglary Devices Using a Siren Driver Supervising the Alarm Output To install a siren driver, perform the following steps: To wire the alarm output using the supervision...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Incoming Handset Telco Line TERMINALS EARTH GROUND ON CONTROL INCOMING TELCO LINE DIRECT CONNECT CORD RJ31X PREMISES RING JACK PHONES PLUG Figure 3-8: Telephone Line Connections Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9 •...
Ionization, direct wire System Sensor 1412 These smoke detectors are UL Listed for use Wiring 4-Wire Smoke Detectors with the VISTA-128BP/VISTA-250BP and are the only 2-wire smoke detectors that may be Power to 4-wire smoke detectors must be used. supervised with an EOL device (use a System...
VISTA-128BP/VISTA-250BP Installation and Setup Guide AUXILIARY POWER TERMINALS 4-WIRE EOL POWER SMOKE SUPERVISION DETECTORS RELAY MODULE A77-716B NOTES: · PROGRAM THE RELAY TO NO CONNECTION SHOWN POWERED. TRANSFER ON FIRE ZONE RELAY OPENS WHEN POWER IS LOST. RESET (ACTIVATION CODE 54).
Section 3 - Installing the Control CONTROL PANEL – 4-WIRE SMOKE EOL POWER DETECTORS SUPERVISION RELAY MODULE A77-761B SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST 2000 JUMPER EOLR HEAT DETECTOR JUMPER P1 ON 333 MODULE MUST BE IN "B" POSITION FOUR-WIRE DETECTOR CIRCUIT TO FIRE ZONE TERMINALS...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Using 2-Wire Latching Glassbreaks on Zone 8 GLASSBREAK DETECTOR Zone 8 can support 2-wire glassbreak detectors. The ZONE 8 zone provides enough standby current to power up to 2000 OHMS 50 2-wire glassbreak detectors meeting the...
4293SN Serialized 1-Zone Expander deviate from these parameters, refer to the application 4190SN Serialized 2-Zone Expander note on the Honeywell website for additional polling loop wiring configurations. To access the application note: 998MX Serialized PIR Go to the honeywell.com/security website Click the Honeywell Security &...
VISTA-128BP/VISTA-250BP Installation and Setup Guide To install polling loop devices, perform the following Polling Loop Supervision steps: A short on the polling loop is indicated by a trouble on Step Action zone 997 and reports as a trouble condition only. If Select devices from the list of compatible annunciation is desired, program the zone as type 05.
Section 3 - Installing the Control INPUT POLLING LOOP EXTENSION POLLING LOOP 4297 CONTROL PANEL OTHER RPMS EXTENSION POLLING LOOP LIMITS = SAME AS INPUT LOOP INPUT LOOP LIMITS: • 128 mA MAX. LIMIT CURRENT TO 64mA ON ANY INDIVIDUAL WIRE RUN. •...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Installation and Setup of 5881 RF Receivers • Zones 988 and 990 are used to supervise the RF reception of receivers 2 and 1, respectively. The reception is supervised for two conditions: Take note of the address you select for the RF receiver, as this address must be enabled in The receiver goes “deaf”...
Section 3 - Installing the Control ANTENNAS TO CONTROL'S REMOTE KEYPAD CONNECTION POINTS. USE MAX. of 220 ft. [67m of #22 (0.64mm) WIRE or 550 ft. (168m) of #18 (1mm) WIRE INSERT IN CIRCUIT FOR EACH RUN. OBSERVE 20 ft. MAX. RIGHT-HAND BOARD FOR COMMERCIAL FIRE INSTALLATIONS.
Page 32
VISTA-128BP/VISTA-250BP Installation and Setup Guide • Some transmitters have built-in tamper protection, For button-type transmitters (wireless keys), such as the 5804 and 5804BD, you must assign a and annunciate a “CHECK” or “TRBL” condition if unique zone number to each individual button covers are removed.
Section 3 - Installing the Control J7 CONNECTOR 4142TR CABLE GRAY (GROUND) GROUND START TRIGGER YELLOW (OUT 1) GROUND BLUE WHITE (GROUND) START RED (OUT 2) MODULE TO AUX. POWER BLACK GREEN (GROUND) TERM. 7 (CUT ORANGE BROWN (OUT 3) JUMPER) TO AUX.
Connect the negative side of the smoke detectors to terminal 7 of the control. Remote Keypad Sounder This feature is available in the VISTA-128BP To duplicate the keypad sounds for a particular partition, program that partition number in field ✳15.
Installing the VA8200 Panel Link Module The VA8200 Panel Link Module (PLM) connects to the Mounting and Wiring the Panel Link Module keypad (ECP) terminals on the VISTA-128BP/VISTA- • The PLM will not operate until the device is 250BP and also connects to other PLMs via the RS-485 enabled in the control’s Device...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Long Range Radio Connected to the J7 Triggers These triggers may be used to trip auxiliary alarm The fire and burglary/audible panic alarm triggers are signaling equipment such as ADEMCO’s 7720, normally LOW and go HIGH until a User Code + 7720ULF, and 7920SE Long Range Radios.
Section 3 - Installing the Control Supervision The data lines between the control and the LRR, as BLACK well as certain functions in the radio, can be ECP RADIO GREEN supervised. YELLOW If communication is lost or a trouble condition occurs, both the LRR and the control’s dialer can be CONTROL programmed to send a Trouble message to the central...
Page 40
Wiring the Alpha Pager Module Close The Alpha Pager Module connects via the 4142TR Other cable to the J8 connector on the VISTA-128BP/VISTA- 250BP. Alphanumeric To wire the Alpha Pager Module, refer to Figure 3-30 PP Date Time EA ZZZ SSSS AD...
The VISTA- VISTA-128BP/VISTA-250BP keypad. 128BP supports up to 8 modules, the VISTA-250BP • All configurable options for each VistaKey are supports up to 15 VistaKey modules (15 access points).
VISTA-128BP/VISTA-250BP Installation and Setup Guide Connecting the Card Reader Step Action Lead from Reader Lead Color To VistaKey TB3 Connect the leads to TB1 in the following Terminal # order: Green LED Orange a. All ground leads to terminals 2, 5, and 9.
Wiring the VISTA Gateway Module GREEN The VISTA Gateway Module is connected between the BLACK CONTROL’S ECP bus (VISTA-128BP/VISTA-250BP keypad KEYPAD TERMINALS YELLOW terminals) and the network bus of the PassPoint Access Control System. See Figure 3-32 for the proper Figure 3-32: Wiring the VISTA Gateway Module wiring connections.
VISTA-128BP/VISTA-250BP Installation and Setup Guide NOTE: See the Home Automation software J8 CONNECTOR instructions for details concerning its operation. 4142TR CABLE (SUPPLIED WITH 4100SM) 4100SM SERIAL MODULE To TB6 Aux. Power (+) + PWR (25mA current draw) To TB7 Aux. Power (-)
Section 3 - Installing the Control • If touch-tones are not present following Step Action phone access to the security system via an Connect the module to the phone line as on-premises phone , try reversing the pair of shown below. See Figure 3-35. wires connected to terminals 3 and 4 on the 4285/4286 Terminal Connects to direct...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Installing the Audio Alarm Verification Module Audio Alarm Verification (AAV) is not permitted If the phone plug is disconnected from the in UL installations. control, the premise’s phones will not operate. NOTES: • 685 Receiver software must be rev. 4.6 or •...
Section 3 - Installing the Control UVCM AND UVST SUMMARY OF CONNECTIONS Refer to UVS Installation and Setup Guide K4214 for complete information SWITCH BANK 2 NOTE 1: CONNECT TO PROPER EARTH GROUND. SWITCH BANK 1 NOTE 2: POWER MAY ALSO BE SUPPLIED BY A LISTED CLASS 2 FUTURE USE, SET TO ON UVST 1 AUX AUDIO, ON = ENABLED POWER SUPPLY RATED 12VDC, MIN 600mA CONNECTED TO THE...
Page 48
VISTA-128BP/VISTA-250BP Installation and Setup Guide NOTE: The keypad connected to the TeleSmart Step Action module must be the 6139T. Connect keypad wiring as shown in (Figure 3-39) (see the chart below for the maximum wire run length for wire gauge you are using).
Section 3 - Installing the Control RING INCOMING PHONE LINE GREEN TYPICAL CONTROL’S PHONE TERMINALS PREMISES PHONES RJ31X RING LOCAL INCOMING BROWN GREY GREEN FROM RING CONTROL DIRECT BROWN HOME CONNECT RING GREY PHONES CORD phon_conn-V0 Figure 3-37: TeleSmart Phone Connections NOTE: If the system hangs up the phone line when calling in from a remote location, check the phone connection terminals (Term.
Section 3 - Installing the Control Connecting the Transformer For Household Burglary-Only Installations: The This product uses the 1361 transformer (1361CN in total current drawn from the alarm output may be up Canada). If you are using X-10 devices, the 1361X10 to 1.7A.
VISTA-128BP/VISTA-250BP Installation and Setup Guide Panel Earth Ground Connections • In order for the lightning transient protective devices AC Power Outlet Ground: Available from 3- in this product to be effective, the designated earth prong, 120VAC, power outlets only. To test the...
Output. Calculate alarm currents, then add to get all listed outputs from Tables 1 through 3, then the Alarm Output current subtotal. add to get the combined current. Table 3: Alarm Output Current Load Table 4: Total VISTA-128BP/VISTA-250BP Current Load Total Current Total Current Device...
Page 54
VISTA-128BP/VISTA-250BP Installation and Setup Guide Use the Battery Selection Table to select the Connect the battery, referring to Figure 3-42. appropriate battery for the installation. The standby battery is automatically tested for Table 6: Battery Selection Table 10 minutes every 4 hours, beginning 4 hours...
NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. See SECTION 1: General Description for the table listing the differences between the VISTA-128BP and the VISTA-250BP control panels. Program Modes The factory-loaded defaults (✳97) enable...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Entry Errors NOTE: If the number of digits that you enter in a data field is fewer than the maximum permitted (for • If an address is improperly entered, the keypad example, a phone number), the keypad displays the displays “FC.”...
Section 4 – Programming Below is a list of the main menus. For details refer to the VISTA-128BP/VISTA-250BP Programming Guide. MAIN MENU OPTIONS For programming the following: ZONE PROG? • • Zone Number Input Device Type for zone (whether RF, polling loop, 1 = YES 0 = NO •...
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option. 00, or 000+[✳] Zone Number Designations The VISTA-128BP supports up to 128 zones, the Zone Index VISTA-250BP supports up to 250 zones, of hardwire,...
Page 59
Section 4 – Programming Communication Defaults for Zones ZONE # ZONE # ZONE # ZONE # 601-632 800-830 992 (DURESS) WWW.DIYALARMFORUM.COM WWW.DIYALARMFORUM.COM...
VISTA-128BP/VISTA-250BP Installation and Setup Guide ZONE # ZONE # ZONE # ZONE # ALARM RST. TROUBLE TRBLE. RST BYPASS BYP. RST. Zone Response Type Definitions Each zone must be assigned a zone type, which defines Type 04: Interior, Follower the way in which the system responds to faults in that Provides a delayed alarm (using the programmed entry zone.
(controlled by the VISTA-128BP/VISTA- or not an entry/exit delay zone was tripped first. 250BP), ECP relay (4204), or to the access control Assign this zone type to a zone covering an area such system independent of the control panel.
This input type operates in the same manner as other Select when this zone is to be controlled by a keypad VISTA-128BP/VISTA-250BP alarm panel zones and is input (user code + [#] + [7] + [3]) for access control. provided so that a zone in the proximity of the VistaKey can be wired without having to run additional wiring from the control panel.
See the VistaKey-SK Installation and Setup Guide for If the PassPoint ACS has uncommitted zones, these the detailed programming instructions. may be used by the VISTA-128BP/VISTA-250BP as VistaKey Dialer Enables hardwired zones. To program for ACS zone inputs, perform the following steps:...
Enter the partition number Alone Access Control Enter the input type: button RF (03). The VISTA-128BP/VISTA-250BP can be used for access control without interfacing to PassPoint ACS or Enter the loop number. VistaKey. A user can trigger an access point (i.e., door Enroll the serial number strike) for 2 seconds by entering User Code + [0].
Quick Exit is initiated by entering [#] + [9]. This restarts the exit delay. All rules 1 = enable of exit apply, including exit error logic. Quick Exit is not permitted for use with the VISTA-128BP/VISTA-250BP Control Panel in a UL installation. WWW.DIYALARMFORUM.COM WWW.DIYALARMFORUM.COM...
Page 66
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Entry Delay #1 (partition-specific) Entry delay defines the delay time that allows users to re-enter the premises through a door that has been programmed as an entry delay door and disarm Enter 02-15 multiplied by 15 seconds.
Section 5 – Data Field Descriptions FIELD TITLE and DATA ENTRIES EXPLANATION VIP Module Phone Code If a 4285/4286 Voice Module is being used, enter the 2-digit phone code used to access the system. 1-9 = first digit of access code ∗...
Page 68
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION TouchTone or Rotary Dial Select the dialing method for the system 0 = disable 1 = enable If you select TouchTone, make sure the subscriber has requested and is paying for TouchTone service. Note that whether or not TouchTone dialing for call placement is permitted, communication by the use of DTMF signaling (ADEMCO High Speed) will still take place.
Page 69
Section 5 – Data Field Descriptions FIELD TITLE and DATA ENTRIES EXPLANATION Enable Open/Close report for If enabled, whenever the keyswitch is used to arm or disarm the partition, an open/close report is sent to the central station. Keyswitch 0 = disable 1 = enable Normally Closed or EOLR (Zones If 0, end-of-line resistors must be used on zones 2-8.
Page 70
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Dual Reporting If enabled, all reports are to be sent to both primary and secondary phone numbers. 0 = disable 1 = enable NOTE: If used with Split Reporting option 1 (1*34), alarms go to both primary and secondary numbers, while all other reports go to secondary only.
Page 71
Section 5 – Data Field Descriptions FIELD TITLE and DATA ENTRIES EXPLANATION Swinger Suppression (partition- This option limits the number of messages (alarms or troubles) sent for a specific zone in an armed period. The system automatically resets the specific) shutdown for a zone after 48 hours if there are no trips on any zone.
Page 72
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Arms Lobby (partition-specific) If enabled, arming this partition causes the system to attempt to arm the lobby 1*19 partition automatically. To enable this field, field 1*18 must also be enabled 0 = disable (partition-specific).
Page 73
Section 5 – Data Field Descriptions DO NOT cross-zone a fire zone with a burglary zone under any circumstance. Cross a fire zone with another fire zone only, and BOTH must be protecting the same physical area (no walls or partitions separating them). Consult NFPA 72 standard for exact spacing requirements.
Page 74
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION RF Transmitter Low Battery If enabled, the system sends a Trouble message for RF transmitter low-battery 1*29 condition to the central station. Reporting NOTE: The Trouble message will be sent for a transmitter supervision failure, 0 = disable independent of this selection.
Page 75
Only one of the options may be active within the system. 2 = keypad sounds at an auxiliary sounder. Option 2 is available in the VISTA-128BP only. 3 = AAV module. Option 2 applies only to the partition enabled in field *15.
Page 76
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Zone 5 Audio Alarm Verification If enabled, zone 5 is used for 2-way audio (AAV). 1*60 Must be 0 for UL installations. 0 = disable 1 = enable NOTE: Zone 5 cannot be used as protection zone.
Page 77
Section 5 – Data Field Descriptions FIELD TITLE and DATA ENTRIES EXPLANATION Auto-Arm Delay (partition- This is the time between the end of the arming window and the start of auto-arm 2*05 warning time (field 2*06). specific) 00 = no delay. 01-14 times 4 minutes (04-56) delay.
Page 78
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Supervision Pulses for LRR There are three entries in this field as follows: Fire, Burglary/Audible Panic, 2*21 Silent Panic/Duress. 0 = disable 1 = enable If enabled, causes the control to send periodic short pulses on the J7 radio triggers to the LRR.
Page 79
Section 5 – Data Field Descriptions FIELD TITLE and DATA ENTRIES EXPLANATION Pager 1 Partition Enable This field has eight entries, one for each partition. If enabled, the system sends 2*38 messages to Pager 1 for the partition(s). 0 = disable 1 = enable Pager 1 Trigger Event Enables This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close,...
Page 80
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Pager 3 Partition Enable This field has eight entries, one for each partition. If enabled, the system sends 2*52 messages to Pager 3 for the partition(s). 0 = disable...
Page 81
Section 5 – Data Field Descriptions FIELD TITLE and DATA ENTRIES EXPLANATION Pager 5 Partition Enable This field has eight entries, one for each partition. If enabled, the system sends 2*66 messages to Pager 5 for the partition(s). 0 = disable 1 = enable Pager 5 Trigger Event Enables This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close,...
Page 82
VISTA-128BP/VISTA-250BP Installation and Setup Guide FIELD TITLE and DATA ENTRIES EXPLANATION Pager 7 Trigger Event Enables This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close, 2*81 System. 0 = disable If enabled, the system sends a signal to the pager.
VISTA-128BP/VISTA-250BP Installation and Setup Guide Exception Reports Time-Driven Events This option allows the reporting of openings and The system can automatically activate and de-activate closings to the central station only if the arming and relays at predetermined times to turn lights or other disarming occurs outside of the predetermined opening devices on and off.
Section 6 – Scheduling Options Open/Close Schedules Definitions General Additional Schedules The open/close scheduling is controlled by one of three Additional opening and closing schedules can be schedules. Each schedule consists of one time window programmed using the Time-Driven Event for openings and one time window for closings.
VISTA-128BP/VISTA-250BP Installation and Setup Guide Scheduling Menu Mode The #80 Scheduling Menu Mode is used to program Steps to Program Scheduling Options most of the scheduling and timed-event options. Enter Installer Code + [#] + [8] + [0] from the normal This section contains examples of the operating mode.
Section 6 – Scheduling Options PROMPT EXPLANATION Enter 1 to program timed events for relay outputs, additional schedules, and other system functions. Refer to Timed Events ? Time-Driven Event Programming later in this section for detailed procedures. 1 = YES 0 = NO Enter 0 to move to the “Access Sched?”...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Daily Open/Close Schedules Each partition can be assigned one daily open/close Open/Close Schedule Worksheet schedule, plus a holiday schedule. Temporary The following worksheet is an example of the schedules are programmed separately, using the #81 worksheet found in the Programming Guide.
Section 6 – Scheduling Options Holiday Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide. Partition Month/Day 3…16 Holiday Schedule Programming After entering Scheduling Menu Mode, press [0] until the “Holidays ?” prompt appears. PROMPT EXPLANATION Enter 1 to program holiday schedules.
Page 90
VISTA-128BP/VISTA-250BP Installation and Setup Guide Bypass Commands Enter the schedule number (01-20) and time window number (01-20), and note the day of the Action Code Action Action Specifier week the action is desired. Auto bypass – Zone list Zone list # Enter the code for the desired action and Auto unbypass –...
Page 91
Section 6 – Scheduling Options Enter the desired activation time (when the Field *04 must be enabled for randomization. A user action is to take place). Select from: must initiate a random schedule by entering one of the following sequences: Activation Description •...
Page 92
VISTA-128BP/VISTA-250BP Installation and Setup Guide ACTION CODES EXPLANATION ACTION SPECIFIER 06=Relay Group On Actions 06-10 01 RELAY GRP # ? 07=Relay Group Off If you selected actions 06-10, the prompt at the right appears. Enter the relay group number. 08=Relay Group Close for 2 seconds Press [✳] to accept entry.
Section 6 – Scheduling Options ACTION CODES EXPLANATION ACTION SPECIFIER 67=Access Point Partition Actions 67-72 PART? 12345678 Grant If you selected actions 67-72, the prompt at the right appears. Enter the partition 68=Access Point Partition HIT 0-8 to which the action applies. Enter 0 to select all partitions. Enter a partition Grant w/Override number again to deselect it.
VISTA-128BP/VISTA-250BP Installation and Setup Guide Limitation of Access Schedule Worksheet Enter the appropriate time window numbers for each access schedule. Tues Thurs 3…8 NOTE: The holidays used for the access groups are the same as those defined in the holiday schedule.
Page 95
Section 6 – Scheduling Options Temporary Schedule Worksheet Partition/Windows Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM 2…8 Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM Temporary Schedules Programming Enter User Code + [#] + 81 to enter this mode.
VISTA-128BP/VISTA-250BP Installation and Setup Guide User Scheduling Menu Mode The system provides up to 20 “timers” available to the end user to control output devices. The output devices themselves are programmed into the system by the installer during Output Programming in the #93 Menu Mode. The end user needs only to know the output device number and its alpha descriptor.
S E C T I O N Downloading Primer (Remote Downloading is not a UL Listed feature) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • General Information Access Security Downloading allows the operator to remotely access,...
Page 98
VISTA-128BP/VISTA-250BP Installation and Setup Guide The following items must be programmed for Installer Unattended Program Mode unattended download: The Installer Unattended Program Mode allows the • The account number (field ✳32) installer to program fields ✳32, ✳33, and ✳35 without •...
Section 7 – Downloading Getting On-Line with a Control Panel At the protected premises, the control panel must be To download a control without programming any connected to the existing telephone line (refer to information, perform the following steps: SECTION 3: Installing the Control). No programming Step Action of the panel is required before downloading to an...
VISTA-128BP/VISTA-250BP Installation and Setup Guide Scheduled Download The VISTA-128BP/VISTA-250BP can be programmed to The options are as follows: periodically and automatically call the downloader. • Check-in interval (weekly, monthly quarterly, When this option is set up, the system will call the yearly) downloader at a scheduled time.
S E C T I O N Setting the Real-Time Clock • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • General Information This system provides a real-time clock, which must be set in order for the system’s event log to keep track of...
Page 102
VISTA-128BP/VISTA-250BP Installation and Setup Guide WWW.DIYALARMFORUM.COM WWW.DIYALARMFORUM.COM...
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • General Information • A user code other than the installer code The VISTA-128BP allows a total of 150 security access codes to be allocated. The VISTA-250BP allows a total must be programmed in order for the Quick of 250 security access codes to be allocated.
VISTA-128BP/VISTA-250BP Installation and Setup Guide Level 6: Duress Codes Duress Reporting NOTE: A non-zero report code for zone 992 (duress) must be • Sends a silent alarm to a central monitoring station programmed, and partition-specific field *85 if the user is being forced to disarm (or arm) the...
Section 9 – User Access Codes Adding a Master, Manager, or Operator Code Enter Installer Code † + [8] + new user no. (002- During user code entry, normal key depressions at other keypads in a partition are 250) + new user’s code ignored.
* Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). NOTE: The VISTA-128BP allows only 150 user codes. PROMPT EXPLANATION The system detects that the user number is already assigned, and prompts if this is a new user.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Battery Test When AC power is present, the VISTA-128BP/VISTA- If the VISTA-128BP/VISTA-250BP finds that the battery 250BP runs a brief battery test every 60 seconds to voltage is low (less than approximately 11.5V), it...
VISTA-128BP/VISTA-250BP Installation and Setup Guide To perform an armed burglary test, proceed as follows: Step Action Step Action Check the keypad-initiated alarms, if Notify the central station that a test of the programmed, by pressing the panic key pairs system is being performed.
Section 10 – Testing The System Trouble Conditions Check or Trouble Messages Power Failure Display Description Display Description CHECK or This indicates that a problem exists on AC LOSS This indicates that the system is TRBL the zone number displayed. Zone operating on battery power only.
Page 110
VISTA-128BP/VISTA-250BP Installation and Setup Guide Contacting Technical Support Having this information handy will make it easier for us to serve you quickly and effectively. PLEASE, before you call Technical Support, be sure You may contact Technical Support via Toll-Free Fax.
The control cabinet must be protected from unauthorized access. This can be done by installing a tamper switch on the cabinet door (not supplied with VISTA-128BP/VISTA-250BP) or by installing a UL Listed passive infrared detector positioned to detect cabinet access. Wire the selected device to any EOLR-supervised zone (Zone 1-8).
• Also connect the 7720’s radio fault output to one of the VISTA-128BP/VISTA-250BP’ EOLR-supervised zones (i.e., 1-8). Program this zone for a trouble by day/alarm by night (type 05) or a 24-hour alarm (type 07, 08) response to radio faults.
Page 113
Appendix A – Regulatory Agency Statements FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 114
VISTA-128BP/VISTA-250BP Installation and Setup Guide CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-003 NOTICE AVIS L’étiquette d’Industrie Canada identifie The Industry Canada Label identifies certified matériel homologué. Cette étiquette certifie que le equipment. This certification means that the matériel est conforme aux normes de protection,...
A P P E N D I X Summary of System Commands • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • User Code Add A User Code = User Code + 8 + New User Number + New User’s Code Commands...
Page 118
VISTA-128BP/VISTA-250BP Installation and Setup Guide 6160V Physical: Width: 7 3/8 inches Height: 5 5/16 inches Depth: 1 3/16 inches Electrical: Voltage Input: 12VDC Current Drain: 190mA Interface Wiring: RED: 12VDC input (+) auxiliary power BLUE: Not Used GREEN: Data to control panel...
Page 122
VISTA-128BP/VISTA-250BP Installation and Setup Guide California State Fire Marshal (CSFM) ......A-2 Door Status Monitor (DSM) Type 11 ......4-8 Call Waiting Defeat ..........5-10 Download Command Enables ........5-4 Callback..............7-3 Download ID Number..........5-4 Callback Requested ..........7-1 Download Phone Number ......... 5-4 CANADIAN EMISSIONS STATEMENTS ....A-4...
Page 123
Index Force Arm Enable for Auto-Arm ......5-13 Long Range Radio Central Station #1 Category Frwd. Power Loss ........... 3-23 Enable ..............5-6 FSA Modules ............3-17 Long Range Radio Central Station #2 Category Enable ..............5-6 Long Range Radio ECP .......... 4-10 Long Range Radio to ECP ........
Page 125
Index Restore Report Timing ..........5-7 Restrict Disarming............. 6-1 RF Motion (RM) Type 02........3-16, 4-7 Tamper Supervision..........3-10 RF Receiver Supervision Check-in Interval ....5-10 TAP protocol............3-23 RF System Installation Advisories......3-14 Telephone Line Connections ........3-5 RF System Operation and Supervision ....3-13 TELEPHONE OPERATIONAL PROBLEMS ....
Page 126
VISTA-128BP/VISTA-250BP Installation and Setup Guide VIP Module ............. 3-28 VIP Module Phone Code ........... 5-3 VISTA Gateway Module ........3-27, 4-9 X-10 ............... 3-18 VISTA-128B Plus as Stand-Alone Access Control ... 4-10 VISTA-128B PLUS Current Load......3-37 VistaKey ............3-25, 4-9 VistaKey Dialer Enables ..........
Page 127
Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791.
Page 128
ÊK5894V5%Š K5894V5 6/04 Rev A WWW.DIYALARMFORUM.COM WWW.DIYALARMFORUM.COM...