DLP-L43 Mounting the NCS 2002 Shelf on the Wall
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The NCS 2002 requires a minimum of 20.4-inches (518.16-mm) vertical length and a minimum of
Note
25.5-inches (647.69-mm) horizontal width on the wall. Wall mount brackets are used to mount the NCS
2002 shelf assembly on the wall. The type of screws used to mount the brackets on the wall depends on
the wall-type and are not provided by Cisco. The screws used must be able to sustain an overall weight
of at least 20 kg (44 lb).
Procedure
Step 1
Verify that the proper fuse panel has been installed in the top mounting space. If a fuse panel is not present,
you must install one according to manufacturer instructions:
• For a DC power supply, the fuse rating must not exceed 15A.
• For an AC power supply, the fuse rating must not exceed 10A, 15A, or 20A. For North America, the
branch circuit protection must be rated 20A. The overcurrent/short circuit protection must be in accordance
with local and national electrical codes.

Cisco NCS 2000 Series Hardware Installation Guide

70
Mounting the Cisco NCS 2002 Shelf