hit counter script

Cisco Ncs 2000 Series Hardware Installation Guide - Cisco NCS 2006 Hardware Installation Manual

Ncs 2000 series
Table of Contents

Advertisement

Installing the Air Flow Regulator
Procedure
Step 1
Install the ANSI 23-inch adapter plates on the horizontal air plenum.
Step 2
Align the screws to fix the adapter plates to the shelf. Insert the screws and tighten them to a torque value of
11.5 in-lb (1.3 N-m).
Step 3
Install the vertical air plenum to the right of the horizontal plenum.
Step 4
Install the wing head screws from the internal side of the horizontal plenum and tighten the screws to a torque
value of 11.5 in-lb (1.3 N-m).
Step 5
Install the vertical air plenum to the left of the horizontal air plenum. Follow step 4.
Figure 23: Pre-assembling the air plenums
DLP-L71 Installing Pre-assembled Air Plenums in ANSI 23-inch Configuration

Cisco NCS 2000 Series Hardware Installation Guide

39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncs 2002Ncs 201

Table of Contents