Figure 19: AC Power Cord SFS-250V-10A-IS
DC Powered Router
Connections to DC power modules are rated at 20 A maximum. The system accepts a nominal input voltage
of –48 VDC with an operational tolerance range of –40.5 VDC to –72 VDC. One dedicated, commensurately
rated DC power source is required for each power module connection.
Power connections to the each DC power module requires two cables: one source cable and one return cable.
For DC power cables, we recommend that you use 20-A-rated, high-strand-count copper wire cables.
The length of the cables depends on your router location from the source power.
Note
DC power cables are not available from Cisco, but they are available from external commercial cable
vendors.
You must terminate DC power cables using terminal blocks. The terminal blocks are supplied along with the
DC power supply modules from Cisco. The terminal block part number is PC 5/2-STF-7.62 BD:+,- from
Phoenix contact.
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
Power Connection Guidelines
19