hit counter script

Dc Powered Router - Cisco ASR 9001-S Hardware Installation Manual

Hide thumbs Also See for ASR 9001-S:
Table of Contents

Advertisement

Chapter 1
Preparing for Installation
Figure 1-18 AC Power Cord CAB-9K10A-EU
Figure 1-19 AC Power Cord SFS-250V-10A-IS

DC Powered Router

Connections to DC power modules are rated at 20 A maximum. The system accepts a nominal input voltage
of –48 VDC with an operational tolerance range of –48 VDC to –60 VDC. One dedicated, commensurately
rated DC power source is required for each power module connection.
Power connections to the each DC power module requires two cables: one source cable and one return
cable.
For DC power cables, we recommend that you use 20-A-rated, high-strand-count copper wire cables.
The length of the cables depends on your router location from the source power.
Note
DC power cables are not available from Cisco, but they are available from external commercial cable
vendors.
You must terminate DC power cables using terminal blocks. The terminal blocks are supplied along with
the DC power supply modules from Cisco. The terminal block part number is PC 5/2-STF-7.62 BD:+,-
from Phoenix contact.
OL-26701-02
Plug:
M2511
Plug:
EL 212
(SI-32)
Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide
Cordset rating: 10A, 250 V
Length: 8 ft 2 in. (2.5 m)
Cordset rating: 10 A, 250V
Length: 8 ft 2 in. (2.5 m)
Site Requirement Guidelines
Connector: WS 002
Connector: WS 002
1-17

Advertisement

Table of Contents
loading