hit counter script

Enabling The Writecache - Asus RS100-E5-PI2 User Manual

1u rackmount server
Table of Contents

Advertisement

6.3.7

Enabling the WriteCache

You may enable the RAID controller's WriteCache option to improve the data
transmission performance.
When you enable WriteCache, you may lose data when a power interruption
occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
1.
From the Management Menu, select Objects > Adapter, then press
<Enter> to display the adapter properties.
2.
Select Disk WC, then press <Enter> to turn the option On (enabled).
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
3.
When finished, press any key to continue.
6-30
Objects
Management Menu
Adapter
Virtual Drive
Physical Drive
Disk Write Cache - Off(Write Through) or On(Write Back)
Adapter 0
Rebuild Rate = 30
Chk Const Rate = 30
FGI Rate
= 30
BGI Rate
= 30
Disk WC = Off
Read Ahead
= On
Bios State = Enable
Stop On Error = No
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
Disk Coercion = 1GB
Factory Default
Chapter 6: RAID Configuration