6.
Select RAID from the Virtual Drive menu, then press <Enter>.
Select the RAID level from the menu, then press <Enter>.
7.
You need at least two identical hard disk drives when creating a RAID 1 set.
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
8.
When creating a RAID 1 set, select DWC from the Virtual Drive menu, then
press <Enter>.
When creating a RAID 0 set, proceed to step 10.
9.
Select On to enable the Disk Write Cache setting, then press <Enter>.
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Enabling DWC can improve the performance, but with the risk of data loss.
ASUS RS100-E5-PI2
Virtual Drive(s) Configured
LD
RAID
Size
Easy Configuration - ARRAY SELECTION MENU
0 1 156402MB 2 64 KB ONLINE
0
1
Virtual Drive 0
RAID = 1
Size = 156402MB
DWC = Off
RA
= On
Accept
SPAN = NO
Choose RAID Level For This VD
Virtual Drive(s) Configured
LD
RAID
Size
Easy Configuration - ARRAY SELECTION MENU
0 1 156402MB 2 64 KB ONLINE
0
1
Virtual Drive 0
RAID = 1
Size = 156402MB
DWC = Off
RA
= On
Accept
SPAN = NO
Disk Write Cache Setting Of VD
#Stripes
StripSz
PORT #
RAID Level
RAID 0
RAID 1
#Stripes
StripSz
PORT #
Change DWC
O
f
f
On
Status
Status
6-15