Sign In
Upload
Manuals
Brands
Siemens Manuals
Controller
RVL471
Siemens RVL471 Heating controller Manuals
Manuals and User Guides for Siemens RVL471 Heating controller. We have
1
Siemens RVL471 Heating controller manual available for free PDF download: Basic Documentation
Siemens RVL471 Basic Documentation (118 pages)
Heating and Domestic Hot Water Controller
Brand:
Siemens
| Category:
Controller
| Size: 1.53 MB
Table of Contents
Table of Contents
3
1 Summary
11
Brief Description and Key Features
11
Type Summary
11
Equipment Combinations
11
Suitable Sensors
11
Suitable Room Units
12
Suitable Actuators
12
Communication
12
Passing on of Heat Demand Signal
12
Documentation
12
2 Use
13
Types of Plant
13
Types of Houses and Buildings
13
Types of Heating Systems
13
Functions
13
3 Fundamentals
15
Key Technical Features
15
Plant Types with Regard to Heating Circuit
15
Plant Types with Regard to D.h.w. Heating
15
Function Blocks
15
Plant Types
16
Selectable Combinations
16
Heating Circuit Type 1 - Space Heating with Mixing Valve
17
Heating Circuit Type 2 - Space Heating with Boiler
17
Heating Circuit Type 3 - Space Heating with District Heat
18
Heating Circuit Type 4 - Precontrol with Mixing Valve
18
Heating Circuit Type 5 - Precontrol with Boiler
18
Heating Circuit Type 6 - Precontrol with District Heat
19
Plant Type 0 - no D.h.w
19
Plant Type 1 - D.h.w. Storage Tank with Charging Pump
19
Plant Type 2 - D.h.w. Storage Tank with Mixing Valve
19
Plant Type 3 - Storage Tank with Diverting Valve
20
Plant Type 4 - Instantaneous D.h.w. Heating Via Heat Exchanger
20
Plant Type 5 - Only Electric Immersion Heater
20
Summary of Plant Types and Plant Combinations
21
Setting Levels, Function Blocks and Plant Types
22
Heating Circuit Operating Modes
23
Automatic Operation
23
Continuously REDUCED Heating
23
Continuously NORMAL Heating
23
Standby
23
Operating Modes
23
Manual Operation
24
Plant Type and Operating Mode
24
Operating State and Operational Level
25
4 Acquisition of Measured Values
26
Room Temperature (A6, B5)
26
Measurement
26
Handling Faults
26
Room Model
26
Flow and Boiler Temperature (B1)
26
Handling Faults
27
Outside Temperature (B9)
27
Measurement
27
Primary Return Temperature (B7)
27
Secondary Return Temperature (B71)
28
Measurement
28
Handling Faults
28
Flow Temperature (B3)
28
Storage Tank Temperature (B31, B32)
28
5 Function Block "Enduser Space Heating
30
Operating Lines
30
Setpoints
30
General
30
Frost Protection for the Building
30
Heating Program
30
Holiday Program
31
6 Function Block "Enduser D.h.w
32
Operating Lines
32
Setpoint
32
Actual Value
32
7 Function Block "Enduser General
33
Operating Lines
33
Switching Program 2
33
Time of Day and Date
33
Indication of Errors
34
8 Function Block "Plant Type
35
Operating Line
35
General
35
9 Function Block "Cascade Slave
36
Operating Lines
36
Mode of Operation
36
Boiler Sequence Release Integral (KFI)
36
Boiler Sequence Reset Integral (KRI)
36
10 Function Block "Space Heating
37
Operating Lines
37
ECO Function
37
Compensating Variables and Auxiliary Variables
37
Heating Limits
38
Mode of Operation
38
Operating Modes and Operating States
39
Room Temperature Source
39
Optimization
39
Definition and Purpose
39
Fundamentals
39
Process
40
Room Model Temperature
40
Optimum Stop Control
41
Quick Setback
41
Optimum Start Control
42
Boost Heating
42
Room Functions
43
Maximum Limitation of the Room Temperature
43
Room Influence
43
Heating Curve
44
Purpose
44
Basic Setting
44
Deflection
45
Parallel Displacement of Heating Curve
46
Display of Setpoints
46
Generation of Setpoint
47
Weather-Compensated Control
47
Demand-Compensated Control
47
11 Function Block "3-Position Actuator Heating Circuit
48
Operating Lines
48
Limitations
48
Flow Temperature Limitations
48
Setpoint Rise
49
3-Position Control
49
Auxiliary Variables in Interconnected Plants
49
Excess Mixing Valve or Heat Exchanger Temperature
49
Pulse Lock
50
12 Function Block "Boiler
51
Operating Lines
51
Operating Mode
51
Limitations
51
Maximum Limitation of the Boiler Temperature
51
Minimum Limitation of the Boiler Temperature
52
Actions During D.h.w. Heating
52
2-Position Control
52
Control with a Single-Stage Burner
52
Control with a 2-Stage Burner
53
Frost Protection for the Boiler
54
Protective Boiler Startup
55
Protection against Boiler Overtemperatures
55
Operating Mode of Pump M1
56
13 Function Block "Setpoint of Return Temperature Limitation
57
Operating Line
57
Description
57
Minimum Limitation of the Return Temperature
57
Acquisition of Measured Values
57
Mode of Operation
57
Mode of Operation with a Single Device (with no Bus)
58
Mode of Operation in Interconnected Plants
58
14 Function Block "District Heat
59
Operating Lines
59
Limitations
59
Maximum Limitation of the Primary Return Temperature
59
Maximum Limitation of Return Temperature Differential (DRT Limitation)
60
Integral Action Time
61
Minimum Stroke Limitation (Suppression of Hydraulic Creep)
61
Limitation of the Volumetric Flow
61
15 Function Block "Maximum Limitation of the Return Temperature, D.h.w
62
Operating Line
62
Purpose
62
Function
62
16 Function Block "Basic Settings D.h.w
64
Operating Lines
64
Assignment of D.h.w. Heating
64
Program for the Circulating Pump
64
General Mode of Operation
64
Operation of Circulating Pump During the Holiday Period
65
Frost Protection for D.h.w
66
Frost Protection in the D.h.w. Storage Tank
66
Frost Protection in the D.h.w. Storage Tank Flow
66
Frost Protection for the Secondary D.h.w. Flow
66
17 Function Block "Release of D.h.w. Heating
67
Operating Line
67
Release
67
Function
67
Release Programs
67
Heating During the Holiday Period
68
18 Function Block "D.h.w. Priority and Flow Temperature Setpoint
69
Operating Line
69
Settings
69
Priority
69
Absolute Priority
69
Shifting Priority
70
No Priority
70
Flow Temperature Setpoint
70
Maximum Selection
70
D.h.w
71
19 Function Block "D.h.w. Storage Tank
72
Operating Lines
72
Charging
72
Charging with Hot Water
72
Alternate D.h.w. Charging with Hot Water and Electricity
72
Temperature and D.h.w. Switching Differential
73
Boost of the D.h.w. Charging Temperature
74
Maximum D.h.w. Charging Time
74
Setpoint of Legionella Function
74
Forced Charging
75
Protection against Discharging
75
Purpose
75
Mode of Operation
75
Manual D.h.w. Charging
76
20 Function Block "3-Position Actuator for D.h.w
77
Operating Lines
77
Function
77
Flow Temperature Boost
77
Temperature Control
77
Pulse Lock
77
21 Function Block "Derivative Action Time D.h.w. Heating Via Heat Exchanger
78
Operating Line
78
Description
78
22 Function Block "Multi-Functional Relay
79
Operating Lines
79
Functions
79
No Function
79
Outside Temperature Switch
79
ON / off According to the Time Switch
80
Relay Energized in the Event of Fault
80
Relay Energized During Occupancy Time
80
Relay Energized During Occupancy Time (Including Optimizations)
80
Relay Energized, if There Is Demand for Heat
80
Manually on / off
80
23 Function Block "Legionella Function
81
Operating Lines
81
Periodicity of Legionella Function
81
Time of Legionella Function
81
Dwelling Time at the Legionella Setpoint
81
Circulating Pump Operation During the Legionella Function
81
Mode of Operation
81
24 Function Block "Switching Program 3
83
Operating Lines
83
Function
83
25 Function Block "Service Functions and General Settings
84
Operating Lines
84
Display Functions
84
Flow Temperature Setpoint
84
Heating Curve
85
Hours Run Counter
85
Software Version
85
Identification Number of Room Unit
86
Radio Clock, Elapsed Time Since Last Reception
86
Commissioning Aids
86
Simulation of the Outside Temperature
86
Relay Test
87
Sensor Test
87
Test of H-Contacts
88
Auxiliary Functions
88
Frost Protection for the Plant
88
Flow Alarm
89
Manual Overriding of Operating Mode (Contact H1)
90
Pump Overrun
90
Pump Kick
90
Winter- / Summertime Changeover
90
Gain of Locking Signal
91
Entries for LPB
92
Source of Time of Day
92
Outside Temperature Source
92
Addressing the Devices
93
Bus Power Supply
93
Bus Loading Number
94
Heat Demand Output DC 0
94
26 Function Block "Locking Functions
95
Operating Line
95
Locking the Settings on the Software Side
95
Locking the Settings for District Heat on the Hardware Side
95
27 Communication
96
Combination with Room Units
96
General
96
Combination with Room Unit QAW50
96
Combination with Room Unit QAW70
96
Combination with SYNERGYR Central Unit OZW30
98
Communication with Other Devices
98
Data Bus
98
Heat Demand Signal
99
28 Handling
100
Operation
100
General
100
Analog Operating Elements
101
Digital Operating Elements
102
Setting Levels and Access Rights
103
Commissioning
103
Installation Instructions
103
Operating Lines
103
Installation
104
Mounting Location
104
Mounting Choices
104
Electrical Installation
104
29 Engineering
105
Connection Terminals
105
Low-Voltage Side
105
Mains Voltage Side
105
Connection Diagrams
106
Low-Voltage Side
106
Mains Voltage Side
106
30 Mechanical Design
107
Basic Design
107
Dimensions
107
31 Technical Data
108
Advertisement
Advertisement
Related Products
Siemens RVS41.813
Siemens RVA47.320
Siemens RVA53.242
Siemens RVA53.280
Siemens RVP550
Siemens RVD110
Siemens RVP211.0
Siemens RVP201
Siemens RVP200
Siemens RVP210
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL