SL1000/SL1100
Level
IN
Description
Use Program 34-11 : E1 Trunk Basic Setup to define the basic setting of each E1 Trunk.
Program
Input Data
34
Item No.
01
02
03
04
Conditions
• After set Program 34-11-01, System needs to be re-started.
Feature Cross Reference
None
2-342
Trunk Port Number
Name
E1 Trunk Type
Use this option to specify the E1 Sig-
nal type (0 ~ 8). Set this option for
compatibility with the connected
Telco.
MFC Dialing Type
Use this option to specify the MFC
Dialing Type. The following table
shows the available MFC Dialing
Type choices, By default, this option
is 0 (MFC Dialing not used).
MFC Group B
Use this option to enable (1) or dis-
able (0) the MFC Dialing Group B
supervisory signaling. Since not all
central offices provide Group B sig-
naling, set this option for compatibility
with the connected Telco. By default,
this option is Disable (0).
Expected Number of MFC Digits
Use this option to specify the number
of digits in the ANI number. This is
required for ANI since delimiters do
not mark the beginning and end of
the data string. The system must
know how many digits of incoming
ANI Caller ID data to interpret.
Program 34 : Tie Line Setup
34-11 : E1 Trunk Basic Setup
Input Data
0 = Standard Trunk
1 = Argentine Pulsed Clear Back Trunk
2 = Argentine Pulsed Answer Trunk
3 = Brazil With seizure acknowledge Trunk
4 = Brazil Without seizure acknowledge Trunk
5 = Brazil E&M Signal A (Idle = 0) Trunk
6 = Brazil E&M Signal A (Idle = 1) Trunk
7 = Brazil E&M Signal B (Idle = 0) Trunk
8 = Brazil Code for collect call blocking Trunk
0 = MFC Dialing not used
1 = NEC Standard
2 = Argentina
3 = Brazil
4 = Chile
5 = Colombia
6 = Mexico
7 = Venezuela
0 = Disable
1 = Enable
0 ~ 20
ISSUE 1.0
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Default
Program 34 : Tie Line Setup
0
0
0
7