NEC SL1000 Programming Manual (simplify)
Manual System Data Clear
1) Press and hold LOAD button, turn ON KSU while still holding LOAD button
for 10 seconds until blue LED start flashing.
2) Release LOAD button
PCPro
Username: tech
Password: 12345678
Default IP: 192.168.0.10
Programming by Keyphone
Login to System Programming
Press SPEAKER #*#*, enter system password 12345678 HOLD
Logout from System Programming
Press MUTE until Program Mode, press SPEAKER
Phone Button VS Programming Button
MUTE = one step backward
DND = Toggle between upper and lower line
HOLD = Enter go to Next
↑ = next
Setup Date & Time
[10-01-01] Year
[10-01-02] Month
[10-01-03] Day
[10-01-04] Week (1:Sun)
[10-01-05] Hour (24 hour mode)
[10-01-06] Minute
[10-01-07] Second
Setup Toll Restriction Table
Class 1 – International/ No Restriction
Class 2 – STD, HP, Local
Class 3 – HP, Local
Class 4 – Local Only
Class 5 – Intercom Only
Setup Table for Toll Restriction Class 1
[21-05-01] Toll Restriction Class – 1
International Call Restriction Table – 0 (Unassigned)
Setup Table for Toll Restriction Class 2
[21-05-01] Toll Restriction Class – 2
International Call Restriction Table – 1 (Assigned)
[21-06-01] Block International Code – 00, 02, 101, 600
1
↓ = previous
Prepared by Voice IP Solutions (M) Sdn Bhd