Chapter 9 Error code list
Code
Error Messages
E-00
ERROR 00
E-01
ERROR 01
E-02
Overtravel
Stop SW was pressed
E-03
during home positioning
Home position detection
E-04
is out of range
Needle stop position
E-05
error
Needle bar case
E-06
position error
E-07
Needle case lock
E-08
ERROR 08
X-axis home position
E-09
error
E-0A
Thread breakage error
E-0B
ERROR 0B
Lower thread breakage
E-0C
error
E-0D
ERROR 0D
E-0E
ERROR 0E
Needle bar No. reading
E-0F
error
The beam sensor
E-10
turned ON
E-11
X sensor reading error
E-12
Y sensor reading error
9-2
Error
No error occurs.
Either motor of main shaft, X- or Y-
axis, or lower shaft has locked.
Overtravel occurs during home
position detecting movement.
The stop switch is pressed during
home position detecting
movement.
Home position detection out of
range
Needle stop position error
Needle bar case position error
Needle bar case lock
Stop switch or emergency switch
was pressed while the needle bar
case is traveling.
X-axis home position detection
error
Thread breaking error
Stop or emergency stop during
sewing
Lower thread broke during
embroidering.
The machine does not return to the
home position.
Mending finish
Failed in the reading of needle bar
No.
Abort by the beam sensor ON
Failed in the reading of X home
position sensor
Failed in the reading of X home
position sensor
BE-1204B-BC • BE-1206B-BC
Measures
This is not usually displayed.
Press the
or turn on the F/B switch on the
head to either side to restart the home position
detecting movement again.
This is not usually displayed.
Adjust the pulley stop position (100 degrees)
above the needle and press the
the F/B switch on the head to either side.
Adjust the position of needle bar case manually,
then press the
or turn ON the F/B switch on
the head to either side. If the same error occurs
again, the color change proper position sensor is
faulty.
Press the
or turn on the F/B switch on the
head to either side. If the same error occurs
again, the color change mechanism is faulty.
This is not usually displayed.
Turn the power off and on once. If the same
error occurs again, the X-axis mechanism is
faulty.
After passing through the thread, press the
or turn on the F/B switch on the head to either
side.
This is not usually displayed.
After the replacement of the lower thread, press
the
or turn ON the F/B switch on the head to
either side.
This is not usually displayed.
Press the
or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the I/O CPU communication is faulty, or
the color change position sensor is faulty.
Press the
or turn ON the F/B switch on the
head to either side.
Press the
or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the I/O CPU communication is faulty.
Press the
or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the I/O CPU communication is faulty.
or turn on