5.
After adjustment is finished, reset the stop switch.
"Release stop SW to operate!" disappears.
6.
Turn the power switch off once, then on again. Check that the clearance between the movable
knife [4] and the fixed knife [5] is 1 mm.
7.
When adjusting again, follow the step 2 and after.
W1317Q
BE-1204B-BC • BE-1206B-BC
[5]
1mm
[4]
W1320Q
Chapter 8 Adjustment
8-11