Manual Upgrade on a Dual Supervisor Module Switch
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Performing supervisor state verification.
-- SUCCESS
Install has been successful.
Troubleshooting a Nondisruptive Upgrade on a Fabric Switch
When a nondisruptive upgrade begins, the system notifies all services that an upgrade is about to start,
and finds out whether or not the upgrade can proceed. If a service cannot allow the upgrade to proceed
at this time (for example, FSPF timers are not configured to the default value, or a CFS operation is in
progress), then the service will abort the upgrade. In such a context, you will be prompted to enter the
show install all failure-reason command to determine the reason why the upgrade cannot proceed.
...
Do you want to continue with the installation (y/n)?
Install is in progress, please wait.
Notifying services about the upgrade.
[#
Please issue "show install all failure-reason" to find the cause of the failure.<---system
prompt to enter the show all failure-reason command.
Install has failed. Return code 0x401E0066 (request timed out).
Please identify the cause of the failure, and try 'install all' again.
switch# show install all failure-reason
Service: "cfs" failed to respond within the given time period.
switch#
If there are any failures for whatever reason (a save runtime state failure or linecard upgrade failure) once
the upgrade is already in progress, then the switch will be rebooted disruptively because the changes
cannot be rolled back. In such cases the upgrade has failed; you are not prompted to enter the show
install all failure-reason command, and entering it will not yield any useful information.
If further assistance is required to determine why an upgrade is unsuccessful, you should collect the
details from the show tech-support command output, and the console output from the installation, if
available.
Manual Upgrade on a Dual Supervisor Module Switch
If you are a new user, use the install all command to perform a software upgrade. This section is for
Caution
administrators or individuals who are completely familiar with specific switch functions.
You can manually upgrade the BIOS and the loader in any Cisco MDS switch using the procedures
provided in this section. This upgrade process requires you to implement some or all procedures
depending on your switch or network configuration.
This section includes the following topics:
•
•
Cisco MDS 9000 Family CLI Configuration Guide
8-26
]
0% -- FAIL. Return code 0x401E0066 (request timed out).
Preparing for a Manual Installation, page 8-27
Upgrading a Loader, page 8-28
Chapter 8
[n] y
OL-18084-01, Cisco MDS NX-OS Release 4.x
Software Images