Chapter 2
Cabling and Troubleshooting the CSS
To connect the CSS 11503 DC power supply to a power source:
1.
2.
Figure 2-13 Location of the CSS 11503 DC Power Supply Connectors
1
3.
Warning
Before installing a wire, ensure that the polarity of the DC connections is
correct. Reversed polarity causes damage to the DC power supply and can
create a dangerous shock hazard.
Do not consolidate the end of a conductor by soft soldering prior to installation.
4.
78-16421-01
At the rear of the chassis, ensure that the CSS power switch is in the O (off)
position.
Locate the DC terminal block on the rear of the chassis as shown in
Figure
2-13.
-4 8 /- 6 0 V
9 .0 A ,4 3 0
V A
1
2
Terminal block (–, +, and
Using a flat-head screwdriver, loosen the captive screws on the three DC
connectors (labeled from left to right, –, +, and
Install the wires into the appropriate connector. Make sure that the
non-insulated part of each wire is 9 mm (0.35 inches) in length.
Cisco 11500 Series Content Services Switch Hardware Installation Guide
Connecting the Power Cord
2
)
Power switch
, respectively).
2-31