Troubleshooting the CSS Hardware Components
Troubleshooting the CSS 11503 Power Supply
Note
Troubleshooting the CSS 11506 Power Supply
Note
Cisco 11500 Series Content Services Switch Hardware Installation Guide
2-44
The CSS 11503 has one power supply as part of its chassis. When you power on
the CSS, the indications of a successful power up are that its modules boot and
become operational, and the following log message appears:
CHMGR: All power supplies are present (1).
This message is displayed only if the logging level is set to the Info-6 or Debug-7
level.
If you power on the CSS and its modules do not boot as indicated by their Status
LEDs, either:
There is no power to the power supply. Ensure that the CSS has power. Check
•
the power switch, power cord, and power source.
The power supply failed. You must replace the CSS chassis.
•
If the CSS 11506 power supplies power on successfully and the CSS completes
the boot process, the following message appears:
CHMGR: All power supplies are present (3).
This message is displayed only if the logging level is set to the Info-6 or Debug-7
level.
A CSS 11506 can contain a maximum of three power supplies, but it requires two
functioning power supplies to guarantee service.
Chapter 2
Cabling and Troubleshooting the CSS
78-13884-06