hit counter script

Cisco 7606-S Installation Manual page 63

Field-replaceable units (frus)
Hide thumbs Also See for 7606-S:
Table of Contents

Advertisement

Chapter 5
Removal and Replacement Procedures
If the LEDs indicate a power problem, see the
Installing a WS-CDC-2500W Power Supply in a Cisco 7613 Router
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Follow these steps to install a DC-input power supply:
Step 1
Ensure that the system (earth) ground connection has been made. For ground connection installation
instructions, see the
Step 2
Verify that power is off to the DC circuit that is connected to the power supply you are installing.
Use both hands to install and remove power supplies. Each DC-input power supply weighs between 22
Caution
pounds (9.9 kg) and 33 pounds (15 kg).
Grasp the power supply handle with one hand, and place your other hand underneath the power supply.
Step 3
Slide the power supply into the power supply bay. Make sure that the power supply is fully seated in the
bay
Figure 5-67 Handling a DC-Input Power Supply
Tighten the power supply captive installation screws
Step 4
OL-4503-24
INPUT OK LED is green
FAN OK LED is green
OUTPUT FAIL LED is not lit
"System Ground Connection" section on page
(Figure
5-67).
I
0
INPU T
FAN
OUT PUT
OK
OK
FAIL
Removing and Replacing the Power Supply
"Identifying Startup Problems" section on page
3-19.
(Figure
5-68).
Cisco 7600 Series Router Installation Guide
4-2.
5-63

Advertisement

Table of Contents
loading

This manual is also suitable for:

7600 series

Table of Contents